Workaround 2 Using Oracle Ilom Cli - Oracle Sun Fire X4800 Product Notes

Table of Contents

Advertisement

8.
Press ESC in the BIOS Setup Utility to boot the system.

Workaround 2 Using Oracle ILOM CLI

Perform the following actions before upgrading your NEM firmware:
Before You Begin
Download the firmware image for your server or CMM from the platform's product web
site. For details, see https://support.oracle.com.
Copy the firmware image to the system on which the web browser is running, using a
supported protocol (TFTP, FTP, HTTP, HTTPS).
Obtain an Oracle ILOM user name and password that has Administrator role account
privileges. You must have Administrator privileges to update the firmware on the system.
1.
Restart the server and enter the BIOS screen.
When POST messages appear, press F2 to enter the BIOS the BIOS Setup Utility.
Note -
this procedure to ensure that the NEMs are powered-on but the OS does not boot.
Log in to the Oracle ILOM CMM CLI.
2.
3.
Use the cd command to navigate to NEM0.
Type the show command to see the NEM properties, including the firmware
4.
version.
The fru_extra_1 property field identifies the firmware version presently installed on the NEM.
If it is 5.3.3.4 or greater, you do not need to update your NEM firmware.
-> cd /SYS/NEM0
/SYS/NEM0
-> show
/SYS/NEM0
Targets:
You do not need to configure anything in the BIOS the BIOS Setup Utility. It is used in
PRSNT
STATE
ERR
OK
SERVICE
OK2RM
LOCATE
Workaround 2 Using Oracle ILOM CLI
Oracle ILOM Enhancements and Issues
79