New Procedures For Updating Cpld (Cr 7043418); Update Oracle Ilom And Bios Firmware Before Updating Other Device Firmware (Cr 6537282) - Oracle Sun Fire X4800 Product Notes

Table of Contents

Advertisement

c.
Note -
IPv6, use either set /SP/network/ipv6/state = enabled or (with SW 1.6 or newer), use
set /SP/network/state = ipv6-only.
To commit the IPv4 and IPv6 pending network changes, type:
commitpending=true
Note -
terminated when you set commitpending to true. When this happens, log back in using the new
settings.

New Procedures for Updating CPLD (CR 7043418)

The procedures for updating CPLD have changed. For details, refer to Updating the CPLD in
Sun Fire X4800 Server Service Manual.
Update Oracle ILOM and BIOS Firmware Before Updating
Other Device Firmware (CR 6537282)
When updating the firmware for multiple devices, if your list of firmware updates includes
Oracle ILOM and BIOS firmware, update it first.
To modify the IPv4 and IPv6 network properties on the SP, issue the set
command.
IPv4 Example:
set /SP/network state=enabled|disabled pendingipdiscovery=static|dhcp
pendingipaddress=value pendingipgateway=value pendingipnetmask=value
IPv6 Example:
set /SP/network/ipv6 state=enabled|disabled pending_static_ipaddress=value/
subnet_mask_value pending_static_ipgatewayaddress=value
The set /SP/network/state = enabled command does not enable IPv6. To enable
If you are logged in to Oracle ILOM using an Ethernet connection, your connection is
New Procedures for Updating CPLD (CR 7043418)
Oracle ILOM Enhancements and Issues
set /SP/network
75