Network Management Port 1 Does Not Work (Cr 6935471 And 6854694); Start /Sys And Stop /Sys Commands Cause Power Button Pressed Event In Log (Cr 6906176); Event Log Messages Might Be Out Of Sequence And Duplicated (Cr 6915976) - Oracle Sun Fire X4800 Product Notes

Table of Contents

Advertisement

7.
Use the show command to view and confirm the firmware version that is installed
on the NEM.
8.
Repeat steps 1 through 7 for NEM1.
Press ESC in the BIOS Setup Utility to restart the boot process.
9.
Network Management Port 1 Does Not Work (CR 6935471
and 6854694)
The CMM has two network management ports. The connectors are labelled NET MGT 0 and
NET MGT 1.
NET MGT 1 does not work. Use NET MGT 0 to connect the CMM to the Ethernet.
If you need to connect to more than one network, use an external Ethernet switch.
Note -
1, it does not switch ports.
start /SYS and stop /SYS Commands Cause Power Button
Pressed Event In Log (CR 6906176)
When you enter the start /SYS and stop /SYS commands, it causes a Power Button Pressed
event to be logged. This log entry is incorrect.
You can ignore these log entries.
Event Log Messages Might Be Out of Sequence and
Duplicated (CR 6915976)
Messages in the event log might be out of sequence and duplicated. For example:
14
Oracle ILOM allows you to select which management port to use. Even if you select port
Fri Apr 16 05:42:50 2010 IPMI
ID =
a : 04/16/2010 : 05:42:50 : System Firmware Progress : BIOS : Man
agement controller initialization

Network Management Port 1 Does Not Work (CR 6935471 and 6854694)

Log
Oracle ILOM Enhancements and Issues
critical
81

Advertisement

Table of Contents
loading

Table of Contents