11.3.1.3
FACTORY
Functions
FACTORY
Set:
Get:
-
Description
Reset device to factory default
Set:
configuration
Get:
-
Response
~nn@FACTORYSPOKCR LF
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
"#FACTORY",0x0D
11.3.1.4
HELP
Functions
Set:
-
HELP
Get:
Description
Set:
-
Get command list or help for specific
Get:
command
Response
1. Multi-line: ~nn@Device available protocol 3000 commands:CR LFcommand,SP
command...CR LF
2. Multi-line: ~nn@HELPSPcommand:CR LFdescriptionCR LFUSAGE:usageCR LF
Parameters
COMMAND_NAME – name of a specific command
Notes
To get help for a specific command use: HELPSPCOMMAND_NAMECR LF
K-Config Example
"#HELP",0x0D
48
Permission
End User
-
Syntax
#FACTORYCR
-
Permission
-
End User
Syntax
-
1. #HELPCR
2. #HELPSPCOMMAND_NAMECR