Table 3-2. Ups Cabinet Weights - Eaton 93PM-L Installation And Operation Manual

20-120 kw (208v)
Hide thumbs Also See for 93PM-L:
Table of Contents

Advertisement

UPS Installation Plan and Unpacking
The UPS equipment operating environment must meet the weight requirements shown in Table 3-2 and the
size requirements shown in Figure 3-1 through Figure 3-9. Dimensions are in millimeters (inches).

Table 3-2. UPS Cabinet Weights

Model
Eaton 93PM-L 120 with 1 UPM Installed
Eaton 93PM-L 120 with 2 UPMs Installed
Eaton 93PM-L 120 with 3 UPMs Installed
Eaton 93PM-L 120 with 4 UPMs Installed
Eaton 93PM-L 120 with 5 UPMs Installed
Eaton 93PM-L 120 with 6 UPMs Installed
Eaton 93PM-L 120 with 1 UPM Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no breakers)
Eaton 93PM-L 120 with 2 UPMs Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no
breakers)
Eaton 93PM-L 120 with 3 UPMs Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no
breakers)
Eaton 93PM-L 120 with 4 UPMs Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no
breakers)
Eaton 93PM-L 120 with 5 UPMs Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no
breakers)
Eaton 93PM-L 120 with 6 UPMs Installed - Left-Mounted or Right-Mounted Top Entry Wiring Sidecar (no
breakers)
Eaton 93PM-L 120 UPS with 1 UPM Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
Eaton 93PM-L 120 UPS with 2 UPMs Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
Eaton 93PM-L 120 UPS with 3 UPMs Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
Eaton 93PM-L 120 UPS with 4 UPMs Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
Eaton 93PM-L 120 UPS with 5 UPMs Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
Eaton 93PM-L 120 UPS with 6 UPMs Installed - Left-Mounted or Right-Mounted 4-Breaker SIAC-B
3-4
Eaton 93PM-L UPS (20–120 kW, 208V) Installation and Operation Manual P-164000688—Rev 02
Weight
kg (lb)
Shipping
Installed
349 (769)
318 (702)
381 (838)
350 (771)
412 (907)
381 (840)
443 (976)
412 (909)
475 (1045)
444 (978)
506 (1114)
475 (1047)
457 (1007)
426 (940)
489 (1076)
458 (1009)
520 (1145)
489 (1078)
551 (1214)
520 (1147)
583 (1283)
552 (1216)
614 (1352)
583 (1285)
590 (1299)
559 (1232)
621 (1368)
590 (1301)
652 (1437)
621 (1370)
684 (1506)
653 (1439)
715 (1575)
684 (1508)
746 (1644)
715 (1577)
www.eaton.com/powerquality
Point Loading
4 at 80 (176)
4 at 88 (193)
4 at 95 (210)
4 at 103 (227)
4 at 111 (245)
4 at 119 (262)
6 at 71 (157)
6 at 76 (168)
6 at 82 (180)
6 at 87 (191)
6 at 92 (203)
6 at 97 (214)
6 at 93 (205)
6 at 98 (217)
6 at 104 (228)
6 at 109 (240)
6 at 114 (251)
6 at 119 (263)