5. Repeat steps 3 and 4 preceding to purge product from and install sanitizing solution in remaining systems.
CAUTION: Do not allow sanitizing solution to remain in systems longer than recommended
contact time. Exceeding contact time will result in damage to stainless steel components.
INNER SLEEVE
SPRING
OUTER SLEEVE
PHILLIP-HEADSCREW
6. Allow sanitizing solution to remain in systems for not less than 10 or no more than 15 minutes (max)
contact time.
7. Remove tank containing sanitizing solution from system, then connect tanks containing product into
systems.
WARNING: Flush sanitizing solution from systems as instructed. Residual sanitizing
solution left in systems could create a health hazard.
8. Place waste container under dispensing valve. Open dispensing valve to permit product to purge sanitizing
solution from system and dispensing valve. Continue to draw from valve until only product is dispensed
from system, then close valve.
9. Repeat step 8 to purge sanitizing solution out of remaining systems and until only product is dispensed.
WARNING: To avoid possible personal injury or property damage, do not attempt to
remove product tank cover until CO
10. Thoroughly rinse inside and outside of product tank that was used for sanitizing solution to remove all
solution residue.
11. Clean exterior of Unit as instructed in DAILY CLEANING OF UNIT.
KNOB
LEVER
COMPENSATOR ADJUSTING SCREW

FIGURE 5. DISPENSING VALVE PARTS IDENTIFICATION

pressure has been released from tank.
2
KNOB LEVER BONNET
FRICTION WASHER
COMPENSATOR
BALL WASHER
SHAFT AND SEAT ASS' Y
O-RING
BODY
O-RING
19