Replenishing Product Supply; Cleaning And Sanitizing; Daily Cleaning Of Unit; Sanitizing Unit - Cornelius VANTAGE Installation Manual

Pre-mix dispenser
Hide thumbs Also See for VANTAGE:
Table of Contents

Advertisement

REPLENISHING CO
WARNING: CO
CO
(carbon dioxide) gas leaks in the entire CO
2
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on primary CO
(' ' change CO
cylinder' ' ) portion of the dial, CO
2
CO
supply should be checked daily and if necessary, replenished as instructed in SERVICE AND
2
MAINTENANCE section of this manual.

REPLENISHING PRODUCT SUPPLY

Product supply should be checked daily and if necessary, replenished as instructed in SERVICE AND
MAINTENANCE section of this manual.

CLEANING AND SANITIZING

DAILY CLEANING OF Unit

Daily cleaning of Unit should be performed at end of daily operation as instructed in SERVICE AND
MAINTENANCE section of this manual.

SANITIZING UNIT

The product systems should be sanitized as instructed every 90-days as instructed in SERVICE AND
MAINTENANCE section of this manual.The sanitizing procedure should be performed by a qualified Service
Person.
CHECKING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL
FOR RESTRICTIONS
CAUTION: The refrigeration assembly condenser coil must be cleaned every 30-days.
Excessive accumulation of dust, lint, and grease on the condenser coil will restrict air flow
through the coil and cause the refrigeration system to overheat. Operating the refrigeration
system in an overheated condition will eventually lead to compressor failure and will automatically
void the factory warranty.
NOTE: Circulating air required to cool condenser coil is drawn in through grille on top of the hood and
is exhausted out through louvers on sides and back of the hood. Restricting air in and out of Unit will
decrease its cooling efficiency.
Area on top of Unit hood must be kept free of obstructions at all times. Make sure nothing is stored on top of
hood. Cooling Unit condenser coil should be periodically cleaned every 30-days as instructed in SERVICE AND
MAINTENANCE section of this manual.
560001790
SUPPLY
2
displaces oxygen. Strict attention must be observed in the prevention of
2
cylinder regulator assembly 1800-psi gage is in shaded
2
and soft drink system. If a CO
2
cylinder is almost empty and should be changed.
2
12
gas leak is
2
gas will experience
2