Replenishing Product Supply; Product Flavor Change - Cornelius VANTAGE Installation Manual

Pre-mix dispenser
Hide thumbs Also See for VANTAGE:
Table of Contents

Advertisement

4. Position CO
cylinder and secure with safety chain.
2
5. Make sure gasket is in place inside primary CO
cylinder.
6. Open (counterclockwise) CO
fully to back-seat valve. (Back-seating valve prevents leakage around valve shaft).

REPLENISHING PRODUCT SUPPLY

NOTE: The following instructions are applicable only when replenishing with the same flavor product.
Refer to PRODUCT FLAVOR CHANGE when changing product flavor.
1. Disconnect empty product tank from product system.
2. Check product tank quick disconnects for sticky or restricted operation. Wash disconnects in warm water.
3. Connect full tank of product into syrup system.

PRODUCT FLAVOR CHANGE

1. Perform sanitizing procedure on product system product flavor change will be made on.
2. Check product tank quick disconnects for sticky or restricted operation. Wash disconnects in warm water.
3. Connect full tank of new flavor product into product system.
CLEANING CO
SYSTEM CO
2
(see Figures 2 and 6 )
The CO
regulators and CO
2
year under normal conditions and after any servicing or disruption of the CO
BALL SEAT (QUAD RING SEAL) EACH TIME GAS CHECK VALVES ARE SERVICED.
560001790
2
cylinder valve slightly to allow lines to slowly fill with gas, then open valve
2
GAS CHECK VALVES
2
manifold CO
gas check valves must be inspected and serviced at least once a
2
2
*QUAD RING
183294000
RETAINER
183298000
FIGURE 6. CO
2
regulator coupling nut, then install regulator on CO
system. ALWAYS REPLACE
2
BALL
183296000
SPRING
183297000
BODY
183295000
*Quad ring seal must be replaced each
time check valve is serviced.
GAS CHECK VALVE