4. Remove screw securing the hood, then lift the hood straight up to remove from the Unit.
CAUTION: The ice bank around the drop-in refrigeration assembly evaporator coils must be
completely melted before attempting to lift the drop-in refrigeration assembly up and out of
the Unit lower cabinet assembly. Attempting to lift the drop-in refrigeration assembly and
ice bank together up out of the Unit lower housing assembly may cause damage to the evaporator
coils.
CAUTION: Never use an ice pick or other instrument to remove ice from the drop-in
refrigeration assembly evaporator coils. Such practice can result in a punctured
refrigeration circuit.
5. Allow the ice bank around the drop-in refrigeration assembly evaporator coils to completely melt. Hot water
may be used to speed up the melting process.
6. Remove four screws securing the drop-in refrigeration assembly in the Unit lower housing assembly.
7. Very carefully, lift the drop-in refrigeration assembly up and out of the Unit lower housing assembly.
8. Use a fiber brush and carefully clean mineral deposit build-up from the agitator motor shaft and the ice
bank sensor.
9. Wash inside of the water tank and the drop-in refrigeration assembly evaporator coils, then rinse with clean
water.
10. Install plug in end of the water tank drain hose.
11. Very carefully, install drop-in refrigeration assembly in Unit lower housing assembly by reversing the
removal procedure.
12. Fill the water tank with clean water until water runs out of the water tank overflow hose. USE
LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS.
13. Plug Unit power cord into electrical outlet. The refrigeration system will start after a 2-minute time delay.
14. Install Unit hood and secure with screw.
15. Install Unit front access panel and secure with two screws.
REPLENISHING CO
WARNING: CO
CO
(carbon dioxide) gas leaks in the entire CO
2
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on CO
(' ' change CO
cylinder' ' ) portion of dial, CO
2
1. Fully close (clockwise) CO
2. Slowly loosen primary CO
regulator assembly from empty CO
3. Unfasten safety chain and remove empty CO
WARNING: To avoid personal injury and/or property damage, always secure CO
upright position with safety chain to prevent it from falling over. Should valve become
SUPPLY
2
displaces oxygen. Strict attention must be observed in the prevention of
2
cylinder primary CO
2
cylinder is almost empty and should be changed.
2
cylinder valve.
2
regulator assembly coupling nut allowing CO
2
cylinder.
2
2
and soft drink system. If a CO
2
regulator assembly 1800-psi gage is in shaded
2
cylinder.
21
gas leak is
2
gas will experience
2
pressure to escape, then remove
2
cylinder in
2
560001790