Chapter 2
The multi sensor standard has a white plate attached to it, so that a reference value can be calculated during carriage height measurement by measuring the intensity
of light reflected upon the white plate.
(Service mode: SERVICE MODE>ADJUST>GAP CALIB)
h) Rail cleaner
The shaft cleaner located in the right rear of the carriage helps keep the main rail clean.
i) Internal unit temperature sensor
One thermistor is installed on the head relay PCB on the back of the head holder to detect the internal unit temperature.
2-36
[1]
[2]
[3]
[10]
[8]
[1]
Carriage relay PCB
[2]
Multi sensor
[3]
Head relay PCB
[4]
Lift cam sensor
[5]
Sensor flag
[6]
Lift cam
[7]
[5]
[4]
[9]
[11]
F-2-18
T-2-10
[7]
Shaft cleaner
[8]
Maintenance jet tray
[9]
Carriage HP sensor
[10]
Multisensor reference
[11]
Head management sensor unit