Figure 7-56 Setting parameters for grid connection data feedback
7.9.2.4 Setting NetEco Parameters
To set parameters correctly, ensure that the SmartLogger can connect to the Huawei NMS
such as NetEco and FusionSolar, or a third-party NMS.
You need to log in as Advanced User that has the permission to set the parameters. Choose
Settings > NetEco to enter the page.
Issue Draft A (2017-02-15)
Start current and End current indicate the valid value range of signals carried by the analog output
loop. The current range is less than or equal to the current range specified in the AO specifications.
Start Data corresponds to End Data.
Start Data and End Data are the valid signal value range of the selected Feedback Parameter. Set
the two parameters based on site requirements. An excessive range results in low precision of the
feedback while an insufficient range results in the incompleteness of the feedback.
Unit is the unit for the selected Feedback Parameter. When setting Start Data and End Data, note
the unit selected. Otherwise, false input and output may be generated.