Huawei SmartLogger2000 User Manual page 198

Hide thumbs Also See for SmartLogger2000:
Table of Contents

Advertisement

SmartLogger2000-(10-C, 11-C)
User Manual
Item
Language
Dimensions (W x H x
D)
Weight
Operating temperature
Storage temperature
Relative humidity (non-condensing)
Protection level
Installation mode
Altitude
a: When the altitude ranges from 3000 m to 4000 m, the temperature decreases by 1° C for
each additional 200 m.
Ports
Item
Ethernet electrical port
Ethernet optical port
PLC port
RS485
USB
Digital input
Digital output
Analog input
Analog output port
Issue Draft A (2017-02-15)
Including mounting
ears
Excluding mounting
ears
SmartLogger
10/100 M
100 M
1
6; supported baud rates: 2400 bit/s, 4800 bit/s, 9600
bit/s, 19,200 bit/s, and 115,200 bit/s
USB2.0
8, supporting only the access from relay dry contacts
3, relay dry contact output, normally open by default,
supporting the 12 V @ 200 mA power source
2, PT100/PT1000 port
7
4, 4–20 mA and 0–20 mA current output
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
SmartLogger
English, Chinese, German, Italian,
French, Japanese, and Russian
411 mm x 170 mm x 58.6 mm
350 mm x 170 mm x 43.6 mm
2.39 kg
–40° C to +60° C
–40° C to +70° C
5%–95%
IP20
Installed on a wall or guide rail, or
inside Huawei smart array controller
a
4000 m
a
b
11 Technical Specifications