Plena Voice Alarm System | Installation and User Instructions | Introduction
3.4

Hotel

3.4.1
Introduction
Smaller hotels are typical examples of applications with
relatively few zones, each with a medium to high output
power requirement. The priorities are speech
intelligibility and compliance with IEC60849 standard.
In addition to mandatory voice alarm functionality for
evacuating guests and staff, an EVAC system for a hotel
should also include BGM in the restaurant, bar and
lobby, plus public address functionality for general
paging. To ensure that all guests hear an emergency
message, the power output per zone is relatively high.
Outside areas such as car parking garages, require
weatherproof horn loudspeakers.
3.4.2
Summary of requirements
Typically 10 to 20 zones in small hotels
Speech intelligibility is the main priority
High power requirement (multiple loudspeakers) per
floor
Fireman's panel by fire exit
Call stations in reception and office
Additional public address functions for paging guests
BGM in lobby and restaurant
3.4.3
Solution for a 12-zone system
A Plena Voice Alarm System Controller handles
routing to up to 6 zones, the additional 6 zones require a
router. Both the reception and office are equipped with
call stations plus keypads for individually addressing
zones, while a fireman's panel (with overall priority) is
built in by the emergency exit. The Plena Voice Alarm
System is a two-channel system, so BGM can still be
provided in zones not receiving a call.
Bosch Security Systems | 2006-06 | 9922 141 10377 en
3.4.4
Power requirements
The system controller features a built-in 240 W power
amplifier, able to drive up to 40 loudspeakers (6 W).
Additional Plena Power Amplifiers are incorporated to
provide additional power, two-channel operation and
spare amplification. To facilitate phased evacuation
from different floors of the hotel, guest areas are divided
into separate zones, each fitted with 13 ceiling
loudspeakers in the corridors. The bar uses cabinet
loudspeakers, while the parking garage uses
weatherproof horn loudspeakers.
3.4.5
Layout
See figure 3.4, table 3.7 and table 3.8
table 3.7: Zones
Zone
Description
Z1
Bar
Z2
Restaurant
Z3
Lobby
Z4
Office
Z5
Kitchens
Z6
Parking garage
Z7-12
Floors 1 to 6
Total
table 3.8: Units
Unit
Description
LBB1990/00
Controller
LBB1992/00
Router
LBB1996/00
Remote control
LBB1997/00
Remote control extension
LBB1956/00
Call station
LBB1957/00
Call station keypad
LBB1935/00
Power Amplifier (240 W)
LBB1938/00
Power Amplifier (480 W)
PLN-DVDT
DVD Tuner
en | 21
Power
3 x 6 W
6 x 6 W
2 x 6 W
1 x 6 W
2 x 6 W
3 x 10 W
78 x 6 W
582 W
No.
1 x
1 x
1 x
1 x
2 x
3 x
1x
2 x
1x