1. IF YOU REPLACE THE MAIN PCB ASSY
<What to do after replacement>
• Installing firmware (Panel Main Firm / Main Firm)
• Setting by country
• Initializing the EEPROM of the main PCB ASSY
• Setting serial number
• Acquiring white level data
• Setting double feeding sensor threshold
• Checking operation after repair
What you need to prepare
(1) One USB cable
(2) Create a temporary folder on the C drive of the computer (Windows
(3) Service setting tool (brusbsn.zip)
Copy this file into the temporary folder created on the C drive.
(4) Download utility (Filedg32.exe)
Copy this file into the temporary folder created on the C drive.
(5) Maintenance driver (MaintenanceDriver.zip)
When the maintenance driver is not installed on the computer to be used, copy this file
into the temporary folder created on the C drive, and extract the copied file. Refer to
"APPENDIX 3 INSTALLING MAINTENANCE DRIVER"
(6) Firmware
Main firmware:
(E.g.) LZXXXX_$.upd
Panel main firmware:
(E.g.) LZXXXX_$.upd
(7) Sheet for double feeding sensor threshold setting (LD6340001)
(8) Double feeding sensor threshold setting tool (BrADSmt1.exe)
Copy this file into the temporary folder created on the C drive.
(9) Scan limit sample.
(10) Test chart DS-001 (LD1625001)
LZXXXX : First six digits of the part number of the firmware
$ : Alphabetic character representing the revision version of the
firmware
LZXXXX : First six digits of the part number of the firmware
$ : Alphabetic character representing the revision version of the
firmware
4-1
®
XP or higher).
for the installation procedure.
Confidential