Error code BA00
This error does not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code BB00
---
A white level not within the standard was scanned when function code 55 was executed.
Step
1
Dirty calibration sheet
First side or second side CIS
2
unit failure
3
Main PCB failure
Error code BC00
This error does not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code BD00
---
A black level not within the standard was scanned when function code 55 was executed.
Step
First side or second side CIS
1
unit failure
2
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Replace the calibration sheet with a new one.
Replace the first side or second side CIS unit.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the first side or second side CIS unit.
Replace the main PCB ASSY.
2-19
Remedy
Remedy
Remedy
Remedy