4.4

Troubleshooting for Software Problems

End users can solve problems related to software, for instance, scanning is not possible from
a computer although scanning can be performed from the machine, as long as they follow
the User Check items. If the problem still cannot be solved, follow each procedure according
to the step number in the tables below.

4.4.1 Does not respond to operation from a computer

<User Check>
- Check that the USB cable is not damaged.
- When using an interface switch, check that the correct machine is selected.
- Check the relevant section in the User's Guide.
- Check the driver settings.
- Reset the machine to the default settings. (Refer to the User's Guide.)
- Unplug the AC power cord and then plug the AC power cord again into the outlet.
Step
1
Program malfunction
Connection failure of the front cover
2
sensor harness
Connection failure of the top cover
3
sensor harness
4
Rubber key attachment failure
5
Front cover sensor failure
6
Top cover sensor failure
7
Main PCB failure

4.4.2 Cannot read data

<User Check>
- Check the relevant section in the User's Guide.
- Unplug the AC power cord and then plug the AC power cord again into the outlet.
Step
Connection failure of the front cover
1
sensor harness
Connection failure of the top cover
2
sensor harness
3
Front cover sensor failure
4
Top cover sensor failure
First side or second side CIS unit
5
failure
6
Main PCB failure
Cause
Reinstall the firmware.
Reconnect the front cover sensor harness.
Reconnect the top cover sensor harness.
Reattach the rubber key.
Replace the front cover sensor ASSY.
Replace the top cover sensor ASSY.
Replace the main PCB ASSY.
Cause
Reconnect the front cover sensor harness.
Reconnect the top cover sensor harness.
Replace the front cover sensor ASSY.
Replace the top cover sensor ASSY.
Replace the first side or second side CIS
unit.
Replace the main PCB ASSY.
2-33
Remedy
Remedy