Error code BE00 to C600
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code C700
Out of Memory
Press Stop
There is insufficient memory to expand scan data.
<User Check>
• Delete scan data stored in the memory.
Step
1
Main PCB failure
Error code C800 and C900
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code CA00
Unusable Device
Remove USB device. Turn the machine off and then back on again. Retry using a
USB flash memory drive.
A USB device not within the specifications is connected to the USB terminal, resulting in
overcurrent.
<User Check>
• Disconnect the USB device not within the specifications.
Step
1
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.