ATTENTION: Environment and Enclosure
This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as
defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.
This equipment is not intended for use in residential environments and may not provide adequate protection to radio
communication services in such environments.
This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those
specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from
accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame,
complying with a flame spread rating of 5VA or be approved for the application if nonmetallic. The interior of the enclosure must be
accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific
enclosure type ratings that are required to comply with certain product safety certifications.
In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for additional installation requirements
• NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures
Rockwell Automation Publication 1783-UM007G-EN-P - February 2017

Install Stratix 8000 and 8300 Switches

Topic
Specifications
Overview
Parts List and Required Tools
Attach Expansion Modules
Mount the Switch
Install an SFP Module
Ground the Switch
Wire the DC Power Source for the Switch
Wire the DC Power Source for the PoE Expansion Module
Attach the Power and Relay Connector to the Switch to the Switch
Attach the Power Connector to the PoE Expansion Module
Wire External Alarms
Connect to 10/100 Copper Ports
Connect to a PoE Expansion Module Port
Connect to Dual-purpose Uplink Ports
Connect to 100BaseFX Ports
Install or Remove the CompactFlash Card
6
Chapter
Page
159
160
162
164
166
169
171
172
174
176
178
178
180
180
181
182
182
157

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stratix 5400 and is the answer not in the manual?

Table of Contents

Save PDF