Transmit Power Alignment - Motorola HT 1000 User Manual

Table of Contents

Advertisement

Transmit Power
Alignment
BBC
Programming Procedure
28
From the MAIN MENU, press F2 twice and then F3 to access the
TRANSMIT POWER ALIGNMENT screen.
MOTOROLA Radio Service Software
HT/JT/VISAR
Model:
Serial:
SERVICE:XMIT ALIGN:XMIT PWR
Test
Current Value
Frequency
Power Level
High
450.02500
43
465.22500
48
475.22500
51
485.97500
56
500.27500
63
511.97500
68
519.97500
48
0
MIN |----+----+----+-X--+----+----+----+----+----+----+----+----| MAX
F1
F2
F3
HELP
Refer to your Radio Service Manual for the Transmitter Power
Alignment procedure.
This procedure should be attempted only by qualified
!
service personnel. Failure to perform alignment
procedures properly may result in seriously degraded
Caution
radio or system performance.
Note: Lower power tuning is not applicable to 800 MHz or low-band
models.
1. Press F6 at the TRANSMIT POWER screen to key up the radio and
toggle PTT. The radio's RF output must be terminated into a 50
ohm load. A three-minute time-out-timer is enabled when the
radio is keyed.
Test frequency and current high and low power levels are shown
on the left side of the screen. The status bar at the bottom of the
screen shows the actual setting in relation to the minimum and
maximum settings allowed for transmission power. If an error
occurs, a pop-up message will appear to indicate the type of error
that occurred. (Refer to the list of computer-to-radio
communication error codes in the Appendix.)
2. While the radio is transmitting, modify the TX power softpot
setting using the UP/DOWN arrow keys. Use the Shift-UP/DOWN
arrow keys to increase the adjustment speed.
Note: A relative TX power value will be displayed, but you must
measure the actual RF power with a service monitor.
Use<:or <SHIFT><<SHIFT>:keys to change
and <ENTER> to go to next softpot.

Transmit Power Alignment

------------------------
Low
72
73
74
76
79
82
84
F4
F5
F6
F7
TOGGLE
PTT
New Softpot Value
Power Level
High
Low
43
72
48
73
51
74
56
76
63
79
68
82
48
84
127
F8
F9
F10
PROGRAM
EXIT
VALUE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VisarJt1000

Table of Contents