Emer Long Press Period (sec)
Mandown Pre-Alert Delay (sec)
Mandown Post-Alert Delay (sec)
118
Enter the desired value directly or use the UP/DOWN arrow keys to
make your selection. This is the length of time (in seconds) that the
radio's Emergency button must be held down in order to terminate the
Emergency mode. Terminating Emergency will cancel any remaining
Emergency message retries and remove the radio from the
unconditionally muted state in the case of Silent Emergency. The valid
range is one to 16 seconds in one-second increments.
The default is 5 seconds.
This field will not be visible for VISAR models. Enter the desired value
directly or use the UP/DOWN arrow keys to make your selection. This
is the time delay between closure of the mandown switch and
initiation of the mandown alert tone. The valid range is 0 (zero) to 8
seconds in one-second increments.
The default is 5 seconds.
This field will not be visible for VISAR models. Enter the desired value
directly or use the UP/DOWN arrow keys to make your selection. This
is the time delay between the mandown alert tone and the actual
transmission of the emergency alarm sequence. The valid range is 0
(zero) to 8 seconds in one-second increments.
The default is 5 seconds.