Registration Via Auto-Add Constraints; Quality Check - Leica ScanStation P30 Basic Training Manual

Hide thumbs Also See for ScanStation P30:
Table of Contents

Advertisement

All ScanWorlds from Group 1 are displayed now and the alignment can be visually checked.
When happy with the results, this view can either be stored or discarded.
Figure 40
Refer also to section 4.7 Visual Quality Check.

4.4 Registration via Auto-Add Constraints

The Auto-Add Constraints function is searching all ControlSpaces of all ScanWorlds to find
objects (e. g. target constraints), which can be used for connecting the ScanWorlds together.
The outer part of the castle (Station 1 and Station 8 – 15) was scanned with sufficient targets
to ensure they can be connected to each other and the inner courtyard using targets only. We
can therefore use the Auto-Add constraints function to find and add these targets for
registration.
Open the Registration window
Select Constraint | Auto-Add Constraints
The algorithm searches first for objects with matching Registration Labels and
then for geometrically consistent objects. Any objects found are then added to
the individual ScanWorlds.
Expand the newly added plus signs from the
constraints are found between which Stations.
26 - 52
Module 3.1 – Applied Registration
Close the ModelSpace View
Select No when asked whether to save it
Ungrouped
Figure 41