Within the TruSpace we can then search for the target 2. Use the project layout drawing on
Figure 2 for reference.
From the TruSpace menu, use:
Seek mode to point the black & white target
Zoom in to the target to have a better view
With Pick mode choose a point near the target center
Choose Create Target | Black/White Target... command from the menu
An algorithm is searching for a right angle in the near of the picked point. With the intensity
change between black and white on the target, Cyclone is able to best fit a vertex in the center
of the target.
Visually inspect to vertex position to see if you are happy with the fitting
Enter "2" as TargetID in the Target Identification window
Press OK
The target is then stored in all corresponding ControlSpaces as well, which is essential to be able
to use it in our further registration process.

3.2 Acquiring Targets in the ModelSpace

Target ID 3, which is a mounted 4 ½ inch black & white target must be manually acquired from
ScanWorld "Station-003:SW-003". This time we will use the ModelSpace View to achieve this.

Registration

Figure 11
Figure 12
Module 3.1 – Applied Registration