Cable List - Huawei DBS3900 Installation Manual

Hide thumbs Also See for DBS3900:
Table of Contents

Advertisement

DBS3900 LampSite
Installation Guide
Cable binding
Safety
Requirements for Special Cables
Ethernet Cable

8.4.2 Cable List

This section describes pRRUcable connections.
pRRU3902 Cables
Table 8-9 List of pRRU3901 cables
Cable
Issue 08 (2016-05-30)
The bending radius of a signal cable must be at least five times the diameter of the cable.
Cables of the same type are bound together.
Different types of cables must be separately routed with a minimum spacing of 30 mm
and cannot be entangled.
The cables are bound tightly and neatly and the sheaths of the cables is intact.
The cable ties face the same direction and all cable ties bound at similar positions must
be in a straight line.
The extra length of each indoor cable tie must be cut off. A slack of 5 mm is reserved for
each outdoor cable tie before the extra length is cut off. All cut surfaces are without sharp
edges.
Labels or nameplates are attached to both ends, joints, or turns of cables after they are
installed.
The steel pipe or fire-resistant rigid polyvinyl chloride pipe should be used for the cable
duct or for routing cables. The cross-sectional usage of the cable duct should be 30% to
50% and that of the pipe for routing cables should be 25% to 30%.
Cables are placed away from sharp objects or wall burrs. If these positions are inevitable,
protection pipes are required for the cables.
Cables are routed away from heat sources, or heat-insulation materials are added
between cables and heat sources.
A clearance is reserved at turns of a cable or the position close to a device, facilitating
cable and device maintenance. The recommended clearance is about 0.1 m.
A maximum of 100 Ethernet cables can be bundled if no PVC pipes are used. If pipes are
used, a maximum of 24 Ethernet cables can be led through a pipe. In this case, ensure
that 1/3 space inside the pipes must be vacant.
The point at which an Ethernet cable is bundled must be spaced 400 mm or less from the
Ethernet port on a pRRU.
For the pRRU used in the elevator engine room on the rooftop, generator set for the
subway engine, and equipment room with central air conditioning, Ethernet cables must
be led through metallic conduits that are reliably grounded at both ends.
One End
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8 Installing a pRRU3902 or pRRU3911 or
pRRU3911+WIFI
The Other End
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents