F7: Communication Option Card Settings (Si-Em3, Si-En3, Si-Ep3) - YASKAWA U1000 iQpump MATRIX Drive User Manual

Low harmonic regenerative pump controller
Hide thumbs Also See for U1000 iQpump MATRIX Drive:
Table of Contents

Advertisement

u

F7: Communication Option Card Settings (SI-EM3, SI-EN3, SI-EP3)

F7 parameters are used for EtherNet/IP, Modbus TCP/IP, and PROFINET options. Other parameters in the F7 group are used
for communication-protocol-specific settings. For more details on a specific option card, refer to the instruction manual for
the option.
No.
(Addr.
Name
Hex)
F7-01
(03E5)
IP Address 1
<1>
F7-02
(03E6)
IP Address 2
<1>
F7-03
(03E7)
IP Address 3
<1>
F7-04
(03E8)
IP Address 4
<1>
F7-05
Subnet Mask 1
(03E9)
F7-06
(03EA) Subnet Mask 2
F7-07
Subnet Mask 3
(03EB)
F7-08
Subnet Mask 4
(03EC)
F7-09
Gateway Address 1
(03ED)
F7-10
Gateway Address 2
(03EE)
F7-11
Gateway Address 3
(03EF)
F7-12
Gateway Address 4
(03F0)
F7-13
Address Mode at Startup
(03F1)
F7-14
Duplex Mode Selection
(03F2)
F7-15
Communication Speed
(03F3)
Selection
F7-16
Communication Loss
(03F4)
Time Out
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual
LCD Display
IP Address 1
Sets the most significant octet of network static IP address.
Sets the second most significant octet of network static IP
IP Address 2
address.
Sets the third most significant octet of network static IP
IP Address 3
address.
Sets the fourth most significant octet of network static IP
IP Address 4
address.
Subnet Mask 1
Sets the most significant octet of network static Subnet Mask.
Sets the second most significant octet of network static Subnet
Subnet Mask 2
Mask.
Sets the third most significant octet of network static Subnet
Subnet Mask 3
Mask.
Sets the fourth most significant octet of network static Subnet
Subnet Mask 4
Mask.
Gateway IP Add 1
Sets the most significant octet of network Gateway address.
Sets the second most significant octet of network Gateway
Gateway IP Add 2
address.
Sets the third most significant octet of network Gateway
Gateway IP Add 3
address.
Sets the fourth most significant octet of network Gateway
Gateway IP Add 4
address.
Select the option address setting method
IP Add Mode Sel
0: User Defined
0: Static
1: BOOTP
1: BOOTP
2: DHCP
2: DHCP
Selects duplex mode setting.
0: Half duplex forced
Duplex Select
1: Auto-negotiate duplex mode and communication speed
0: Half/Half
2: Full duplex forced
1: Auto/Auto
3: Half duplex forced (port 1)/Auto-negotiate duplex mode and
2: Full/Full
communication speed (port 2)
3: Half/Auto
4: Half duplex forced (port 1)/Full duplex forced (port 2)
4: Half/Full
5: Auto-negotiate duplex mode and communication speed
5: Auto/Half
(port 1)/Half duplex forced (port 2)
6: Auto/Full
6: Auto-negotiate duplex mode and communication speed
7: Full/Half
(port 1)/Full duplex forced (port 2)
8: Full/Auto
7: Full duplex forced (port 1)/Half duplex forced (port 2)
8: Full duplex forced (port 1)/Auto-negotiate duplex mode and
communication speed (port 2)
Baud Rate
Sets the communication speed
10: 10/10 Mbps
10: 10 Mbps
100: 100/100 Mbps
100: 100 Mbps
101: 10/100 Mbps
101: 10 Mbps (port 1)/100 Mbps (port 2)
102: 100/10 Mbps
102: 100 Mbps (port 1)/10 Mbps (port 2)
Sets the time out value for communication loss detection in
tenths of a second. A value of 0 disables the connection time
CommLoss Tout
out.
Example: An entered value of 100 represents 10.0 seconds.
Description
<2>
B.7 F: Option Settings
Values
Page
Default: 192
Range: 0 to 255
Default: 168
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 20
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 255
Range: 0 to 255
Default: 0
Range: 0 to 255
Default: 192
Range: 0 to 255
Default: 168
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 1
Range: 0 to 255
Default: 2
Range: 0 to 2
Default: 1
Range: 0 to 8
Default: 10
Range: 10 to 102
Default: 0.0 s
Min.: 0.0
Max.: 30.0
297
B

Advertisement

Table of Contents
loading