Checking And Charging The Battery - Yamaha V Star 950 Service Manual

Table of Contents

Advertisement

4. Install:
• Rider seat
Refer to "GENERAL CHASSIS" on page
4-1.
EAS28030

CHECKING AND CHARGING THE BATTERY

EWA13290
WARNING
Batteries generate explosive hydrogen gas
and contain electrolyte which is made of
poisonous and highly caustic sulfuric acid.
Therefore, always follow these preventive
measures:
• Wear protective eye gear when handling
or working near batteries.
• Charge batteries in a well-ventilated area.
• Keep batteries away from fire, sparks or
open flames (e.g., welding equipment,
lighted cigarettes).
• DO NOT SMOKE when charging or han-
dling batteries.
• KEEP BATTERIES AND ELECTROLYTE
OUT OF REACH OF CHILDREN.
• Avoid bodily contact with electrolyte as it
can cause severe burns or permanent eye
injury.
FIRST AID IN CASE OF BODILY CONTACT:
EXTERNAL
• Skin — Wash with water.
• Eyes — Flush with water for 15 minutes
and get immediate medical attention.
INTERNAL
• Drink large quantities of water or milk fol-
lowed with milk of magnesia, beaten egg
or vegetable oil. Get immediate medical
attention.
ECA3D81014
• This is a sealed battery. Never remove the
sealing caps because the balance
between cells will not be maintained and
battery performance will deteriorate.
• Charging time, charging amperage and
charging voltage for an MF battery are dif-
ferent from those of conventional batter-
ies. The MF battery should be charged
according to the appropriate charging
method. If the battery is overcharged, the
electrolyte level will drop considerably.
Therefore, take special care when charg-
ing the battery.
ELECTRICAL COMPONENTS
TIP
Since MF batteries are sealed, it is not possi-
ble to check the charge state of the battery by
measuring the specific gravity of the electro-
lyte. Therefore, the charge of the battery has to
be checked by measuring the voltage at the
battery terminals.
1. Remove:
• Rider seat
• Tool kit tray
Refer to "GENERAL CHASSIS" on page
4-1.
2. Disconnect:
• Battery leads
(from the battery terminals)
ECA3D81022
First, disconnect the negative battery lead
"1", then the positive battery lead "2".
3. Remove:
• Battery
4. Check:
• Battery charge
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect a pocket tester to the battery ter-
minals.
• Positive tester probe →
positive battery terminal
• Negative tester probe →
negative battery terminal
TIP
• The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive bat-
tery terminal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown
in the charts and the following example.
7-82