SmartGUARD Page
After hardware installation, please enter the function menu on the control panel to enable the
SmartGUARD fire alarm.
SmartGUARD Enable / Disable:
Press directional key (left or right) to enable the SmartGUARD device or disable it.
Sensitivity :
Press directional key (left or right) to set the sensitivity of SmartGUARD. There are five
sensitivity settings (1, 3, 5, 7, 9 seconds) that can be selected. Sensitivity is defined by the
delay time from when a fire is detected until the fire alarm alerts user, and automatically
shuts down the system. For example, if the sensor delay switch is set to the 3 second
position, the SmartGUARD will start an alarm and automatically shutdown the laser system
after detecting a fire for 3 seconds.
Relevant Buttons
F1 (Back)
F4 (Save)
/
Directional
/
Directional
Start / Stop
Auto Focus
▲ / ▼ Manual Focus
- 45 -
SmartGUARD Setting Page
Back to previous page
Save your current settings
Cycle SmartGUARD between Disable/ Enable
Scroll through the menu selections
Back to Main Work Page
Initiate the auto focus function
Manually adjust the height of the work table (Z-axis)
LaserPro X252 & X380RX User Manual
☼ Navigating to this page:
Main Work Page
Press F4
Functions Page
Select <Machine Setting>
from the menu
Machine Setting Page
Select <SmartGUARD>
from the menu
Set File Save Mode
Page
Function

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Laserpro x380rx

Table of Contents