MI8 (Figure 21)
ON
RUN
MEANING
IN
EXT
FAIL
Internal fault
0
1
SEL
Compatibility error
1
2
IN
Error in communication
3
4
with master
5
6
Error on other
7
8
slave or M1
Same type of slave with
same address detected
Figure
- MI8
21
40
RUN
IN FAIL
EXT FAIL
GREEN
RED
RED
ORANGE
2 or 3
OFF
OFF
flashes
5
OFF
OFF
flashes
Shows the
5
physical address
OFF
OFF
flashes
of the unit
OFF
ON
OFF
5
5
OFF
flashes
flashes
Table 32 - Troubleshooting MI8
LED
SEL
IN1÷8
OSSD1/2
YELLOW
RED/GREEN
OFF
Red
5
5
flashes
flashes
OFF
OFF
OFF
OFF
OFF
OFF
MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
CLEAR1/2
STATUS1/2
REMEDY
YELLOW
YELLOW
Return the unit to ReeR to
OFF
OFF
be repaired
• Firmware version not
5
5
compatible with M1,
flashes
flashes
return to ReeR for FW
upgrade.
• Restart the system
• If the problem persists,
OFF
OFF
return the MI8 to ReeR to
be repaired
• Restart the system
OFF
OFF
• Check which unit is in FAIL
mode
• Change the unit's address
OFF
OFF
NODE SEL
(see
8540780 • 25th June 2012 • Rev.15
)