Insert the air assembly, shaft first, into the top of the upper tube.
8
Guide the air shaft through the shaft guide in the bottom of the upper
tube.
Thread the top cap into the upper tube and tighten it.
9
24 mm
12.4 N•m (110 in-lb)
200 Hour Service
Continue the 200 Hour Service with
Damper Service - 30™, Judy™, Recon™ -
Silver.
43
Air Spring Installation - Silver