Connection Tightening Torques - Danfoss VLTAutomationDrive FC 360 Quick Manual

Table of Contents

Advertisement

Specifications

8.4 Connection Tightening Torques

When tightening all electrical connections it is very important to tighten with the correct torque. Too low or too high
torque results in a bad electrical connection. Use a torque wrench to ensure correct torque
Frame
size
J1
J2
J3
J4
J5
J6
J7
J7
Table 8.8 Tightening of Terminals
8
8
44
VLT
Power [kW]
Mains
0.37-2.2
1.4
3.0 -55
1.4
7.5
1.4
11-15
1,2
18.5-22
1,2
30-45
2
55
12
75
14
MG06A102 - VLT
®
AutomationDrive FC 360 Quick Guide
Torque [Nm]
DC
Motor
connection
0,8
0,8
0,8
0,8
0,8
0,8
1,2
1,2
1,2
1,2
2
2
12
12
14
14
®
is a registered Danfoss trademark
Brake
Earth
0,8
3
0,8
3
0,8
3
1,2
1,6
1,2
1,6
-
2
-
2
-
2
Relay
0,5
0,5
0,5
0,5
0,5
0.5
0.5
0.5