11 . Separate the 4 parts of the scraper subassembly .
12 . Place the new silicone blade on its support
13 . Gather the 4 parts and screw the 5 fixing screws.
14 . Set the subassembly on the machine : get the silicone blade touching the protection strip, then screw tightly the 5 CHC
M5x12 screws removed at the step 9 .
15 . Proceed steps from 8 to 12 to replace the left silicon scraper .
16 . Turn back the crank handle until the manufacturing chamber is fully closed .
17 . Refit and tighten the 8 screws of the front door of the main cabinet.
18 . Proceed to next procedure . Make sure to put the locking key when all maintenance complete .
91
3D SYSTEMS, INC.
PN:80-D27 Rev.B

Hide quick links:

Advertisement