6 .
Move down the sintering piston about 5-10mm .
7 .
Open the airlock .
8 .
Open the airlock door .
9 .
Load the calibration plate on the sintering plate via the airlock .
10 . Close the airlock door .
11 . Close the airlock .
12 . Launch the inerting process up to reach the fume safety level .
13 . Download the specific manufacturing FAB file on the printer.
14 . Start the draw (layer#0) of the calibration plate with the red point in order to control its positioning . Adjust the
calibration plate if necessary .
15 . Start the draw (layer#0) of the calibration plate without the red point .
16 . Repeat the previous step, to be sure the draw will be well marked .
17 . When job is complete, repeat steps from 6 to 8 to remove the calibration plate from the printer via the airlock .
18 . Close the airlock door and airlock . Then stop the inerting process .
19 . Inspect visually the sintered lines are homogeneously well marked over the whole surface of the plate (1) . If the result is
not correct (2), repeat the draw on a new calibration plate . If the result is still no correct, contact 3D Systems Customer
Support .
Calibration plate with crossing-lines homogeneously well marked
20 . The control of the calibration requires the current
correction file. To export this correction file:
Access to the
Configuration
Go to the
Optic
menu (1),
Click on the
Export
Select "Correction file" from the file list, then save
the file on a folder from your network or a USB
key .
3D SYSTEMS, INC.
tool,
button (2),
1
1
2
96
Calibration plate with crossing-lines
not marked correctly
PN:80-D27 Rev.B