Setting Menu - 3D Systems ProX DMP 300 User Manual

Production
Table of Contents

Advertisement

Setting menu

Setting menu
The
gives access to 2 sub-menus:
Configuration
The
Configuration
tool includes different parameters grouped in 8 tabs . Only the followings tabs are unlocked, the access
to other tabs require higher user level .
For each tab, the read-only value values are displayed in grey, the editable one in black with the blue border . To change the
settings, proceed as follow:
1 .
Click on the value .
2 .
Select/enter the new setting .
3 .
After modification, the new value is shown in red. Click on
4 .
Some modifications require the software control to be restarted. Refer to the
section "Closing / opening PX Control application" on page 66 .
General tab
This tab summarizes several basic
parameters associated to the machine:
Language: select the language
of the sofwtare (English/French)
Machine: specify the type of
printer (ProX DMP300, 200 or
100)
Serial
number: indicate the
serial number indicated on the
name plate of the printer
Piston
reducer: is the printer equipped with special piston reducer? (Yes/No)
Oxygen tab
This tab indicates the settings related to the oxygen value on the manufacturing chamber:
General safety O2
immediately if the oxygen value is upper than this setting . The recycling cycle and the powder vacuum are disabled .
If the setting is null, this function is disabled .
Minimum O2 threshold to launch a
value is upper the setting, starting a job is not permitted for
warning message will be displayed in such case) .
Manufacturing stop
manufacturing will stop at the end of the layer if the oxygen value is upper than this setting . If the setting is null,
this function is disabled .
3D SYSTEMS, INC.
Configuration
threshold: this setting value is an absolute percentage of oxygen . The manufacturing will stop
manufacturing: it defines the minimum value of oxygen to produce. If O2
threshold: this setting value is a percentage relative to the oxygen set point . The
Event
browser .
and
to save the modifications, or
Operator
level and is permitted for other levels (a
52
to cancel .