3
Information area
•
ATMOSPHERE
Gas
•
(mode of the gas supplied): REGUL (regulation around an oxygen target value), DIRECT (continuous injection of
gas at a constant rate), OFF (no gas injection),
•
Status of the gas valve indicator : if green, the valve is opened,
•
O2
value: current oxygen level value in PPM (particles per million) on the manufacturing chamber,
•
O2
setpoint: oxygen level target value,
•
Enclosure
pressure: current pressure value on the manufacturing chamber,
Enclosure
temperature: current temperature value on the manufacturing chamber .
•
•
LENS CLEANER
Turbine: state of the lens cleaner blower (turbine) . If green/white, the blower is operating/not operating,
•
Setpoint: setpoint of the blower operating, in %,
•
Differential pressure
•
•
PART
Clamping: status of the base plate clamp . If green/white, clamping is ON/OFF,
•
Available
powder: the height of the powder available in the feeding piston in mm,
•
Zero
sintering: the zero position of the sintering piston in mm .
•
•
LASER/OPTIC
•
Defocus: defocusing value in mm,
•
Laser
power: current Laser power, in % .
3D SYSTEMS, INC.
: [Outlet Pressure – Inlet Pressure] of the external filter.
49
PN:80-D27 Rev.B