6. DISPLAY AND OPERATION
Name
Within one-revolution
position high
ABS counter
Load inertia moment
ratio
Bus voltage

6.2.3 Changing the status display screen

The status display item of the servo amplifier display shown at power-on can be changed by changing the
parameter No. 18 settings.
The item displayed in the initial status changes with the control mode as follows:
Torque/position
Symbol
Unit
Cy2
100
The within one-revolution position is displayed in 100 pulse
pulse
increments of the encoder.
The value returns to 0 when it exceeds the maximum number of
pulses.
The value is incremented in the CCW direction of rotation.
LS
rev
Travel value from the home position in the absolute position
detection systems is displayed in terms of the absolute position
detectors counter value.
dC
0.1
The estimated ratio of the load inertia moment to the servo motor
Times
shaft inertia moment is displayed.
Pn
V
The voltage (across P-N) of the main circuit converter is displayed.
Control mode
Position
Position/speed
Cumulative feedback pulses/servo motor speed
Speed
Speed/torque
Servo motor speed/analog torque command voltage
Torque
Analog torque command voltage/cumulative feedback pulses
Description
Status display at power-on
Cumulative feedback pulses
Servo motor speed
Analog torque command voltage
6 - 4
Display
range
0
to
1310
32768
to
32767
0.0
to
300.0
0
to
450