5. PARAMETERS

5.2.2 Analog output

The servo status can be output to two channels in terms of voltage. Use this function when using an
ammeter to monitor the servo status or synchronizing the torque/speed with the other servo.
(1) Setting
Change the following digits of parameter No.17:
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The setting
range is between
999 and 999mV.
Parameter No.
31
32
Parameter No. 17
0
0
Used to set the offset voltage for the analog monitor ch1 output.
Used to set the offset voltage for the analog monitor ch2 output.
Analog monitor ch1 output selection
(Signal output to across MO1-LG)
Analog monitor ch2 output selection
(Signal output to across MO2-LG)
Description
5 - 29
Setting range [mV]
999 to 999