Gain Changing Function; Applications; Function Block Diagram - Mitsubishi Electric MR-J2S-*A series Instruction Manual

Melservo servo amplifiers and motors
Table of Contents

Advertisement

8. SPECIAL ADJUSTMENT FUNCTIONS

8.5 Gain changing function

This function can change the gains. You can change between gains during rotation and gains during stop
or can use an external signal to change gains during operation.

8.5.1 Applications

This function is used when:
(1) You want to increase the gains during servo lock but decrease the gains to reduce noise during rotation.
(2) You want to increase the gains during settling to shorten the stop settling time.
(3) You want to change the gains using an external signal to ensure stability of the servo system since the
load inertia moment ratio varies greatly during a stop (e.g. a large load is mounted on a carrier).

8.5.2 Function block diagram

The valid control gains PG2, VG2, VIC and GD2 of the actual loop are changed according to the conditions
selected by gain changing selection CDP (parameter No. 65) and gain changing condition CDS (parameter
No. 66).
External signal
CDP
Command pulse
frequency
Droop pulses
Model speed
CDS
Parameter No.66
CDP
Parameter No.65
Comparator
GD2
Parameter No.34
GD2
Parameter No.61
PG2
Parameter No.35
PG2
PG2B
100
VG2
Parameter No.37
VG2
VG2B
100
VIC
Parameter No.38
VIC
VICB
100
8 - 5
Changing
Valid
GD2 value
Valid
PG2 value
Valid
VG2 value
Valid
VIC value

Hide quick links: