Ordering - GE UR T60 Instruction Manual

Ur series transformer protection system
Table of Contents

Advertisement

2 PRODUCT DESCRIPTION
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
2
Breaker arcing current I
t
Breaker control
Breaker flashover
Breaker restrike
Contact inputs (up to 96)
Contact outputs (up to 64)
Control pushbuttons
Data logger
Digital counters (8)
Digital elements (48)
Direct inputs and outputs (32)
Disconnect switches
DNP 3.0 or IEC 60870-5-104 protocol
Ethernet Global Data protocol (optional)
Event recorder
a) OVERVIEW
The T60 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-
ules: power supply, CPU, CT/VT, digital input and output, transducer input and output, and inter-relay communications.
Each of these modules can be supplied in a number of configurations specified at the time of ordering. The information
required to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).
Order codes are subject to change without notice. CPU modules 9G, 9H, 9L, and 9M are obsolete. See
http://www.gedigitalenergy.com/multilin/order.htm
NOTE
The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules (regu-
lar CT/VT modules or the HardFiber modules). The order code options are described in the following sub-sections.
b) ORDER CODES WITH TRADITIONAL CTS AND VTS
The order codes for the horizontal mount units with traditional CTs and VTs are shown below.
The following features are not available when the T60 is ordered with three CT/VT modules: breaker arcing current,
load encroachment, and breaker failure.
NOTE
GE Multilin
FUNCTION
FlexElements™ (16)
FlexLogic™ equations
IEC 61850 communications (optional)
Load encroachment
Metering: current, voltage, power, power
factor, energy, frequency,
harmonics, THD
Modbus communications
Modbus user map
Non-volatile latches
Non-volatile selector switch
Oscillography
Pilot Scheme (POTT)
Remote RTD inputs
RTD inputs
Setting groups (6)
for the latest ordering options.
T60 Transformer Protection System
2.1 INTRODUCTION
FUNCTION
Time synchronization over SNTP
Transducer inputs and outputs
Transformer aging factor
Transformer hottest-spot temperature
Transformer loss-of-life
Trip bus
User-definable displays
User-programmable fault reports
User-programmable LEDs
User-programmable pushbuttons
User-programmable self-tests
Virtual inputs (64)
Virtual outputs (96)
VT fuse failure

2.1.2 ORDERING