B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 65)
ADDR
REGISTER NAME
Frequency (Read Only)
8000
Tracking Frequency
Temp Monitor Actual Values (Read Only Non-Volatile)
81C0
Reserved Register T1
81C1
Reserved Register T2
B
81C2
Reserved Register T3
81C4
Reserved Register T4
81C6
Reserved Register T5
81C8
Reserved Register T6
81CA
Reserved Register T7
81CC
Reserved Register T8
EGD Fast Production Status (Read Only Non-Volatile)
83E0
EGD Fast Producer Exchange 1 Signature
83E1
EGD Fast Producer Exchange 1 Configuration Time
EGD Fast Production Status (Read Only)
83E3
EGD Fast Producer Exchange 1 Size
EGD Slow Production Status (Read Only and Read Only Non-Volatile) (2 modules)
83F0
EGD Slow Producer Exchange 1 Signature
83F1
EGD Slow Producer Exchange 1 Configuration Time
83F3
EGD Slow Producer Exchange 1 Size
83F4
...Repeated for EGD Slow Producer Exchange 2
EGD Fast Production (Read/Write Setting)
8400
EGD Fast Producer Exchange 1 Function
8401
EGD Fast Producer Exchange 1 Destination
8403
EGD Fast Producer Exchange 1 Data Rate
8404
EGD Fast Producer Exchange 1 Data Item 1 (20 items)
8418
Reserved (80 items)
EGD Slow Production (Read/Write Setting) (2 modules)
8468
EGD Slow Producer Exchange 1 Function
8469
EGD Fast Producer Exchange 1 Destination
846B
EGD Slow Producer Exchange 1 Data Rate
846C
EGD Slow Producer Exchange 1 Data Item 1 (50 items)
849E
Reserved (50 items)
84D0
...Repeated for EGD Exchange 2
Breaker Failure (Read/Write Grouped Setting) (6 modules)
8600
Breaker Failure 1 Function
8601
Breaker Failure 1 Mode
8602
Breaker Failure 1 Source
8603
Breaker Failure 1 Amp Supervision
8604
Breaker Failure 1 Use Seal-In
8605
Breaker Failure 1 Three Pole Initiate
8606
Breaker Failure 1 Block
8607
Breaker Failure 1 Phase Amp Supv Pickup
8608
Breaker Failure 1 Neutral Amp Supv Pickup
8609
Breaker Failure 1 Use Timer 1
860A
Breaker Failure 1 Timer 1 Pickup
860B
Breaker Failure 1 Use Timer 2
860C
Breaker Failure 1 Timer 2 Pickup
860D
Breaker Failure 1 Use Timer 3
860E
Breaker Failure 1 Timer 3 Pickup
860F
Breaker Failure 1 Breaker Status 1 Phase A/3P
8610
Breaker Failure 1 Breaker Status 2 Phase A/3P
8611
Breaker Failure 1 Breaker Test On
B-46
RANGE
2 to 90
-55 to 125
-55 to 125
-2147483647 to
2147483647
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 4294967295
0 to 65535
0 to 65535
0 to 4294967295
0 to 65535
0 to 1
0 to 4294967295
50 to 1000
0 to 65535
---
0 to 1
0 to 4294967295
500 to 1000
0 to 65535
---
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
Hz
0.01
F001
C
1
F002
C
1
F002
---
1
F004
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F001
---
---
F003
---
1
F001
---
1
F001
---
---
F003
---
1
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
DEFAULT
0
-55
125
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0
0
0
0