B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 32 of 65)
ADDR
REGISTER NAME
7144
Ground Distance Zone 1 Z0M Z1 Angle
7145
Ground Distance Zone 1 Voltage Level
7146
Ground Distance Zone 1 Non-Homogeneous Angle
7147
Ground Distance Zone 1 POL Current
7148
Ground Distance Zone 1 Reverse Reach
B
7149
Ground Distance Zone 1 Reverse Reach RCA
714A
Reserved (7 items)
7151
...Repeated for Ground Distance Zone 2
7172
...Repeated for Ground Distance Zone 3
Phase Directional Overcurrent (Read/Write Grouped Setting)
7260
Phase Directional Overcurrent 1 Function
7261
Phase Directional Overcurrent 1 Source
7262
Phase Directional Overcurrent 1 Block
7263
Phase Directional Overcurrent 1 ECA
7264
Phase Directional Overcurrent 1 Pol V Threshold
7265
Phase Directional Overcurrent 1 Block Overcurrent
7266
Phase Directional Overcurrent 1 Target
7267
Phase Directional Overcurrent 1 Events
7268
Reserved (8 items)
Neutral Directional Overcurrent (Read/Write Grouped Setting)
7280
Neutral Directional Overcurrent 1 Function
7281
Neutral Directional Overcurrent 1 Source
7282
Neutral Directional Overcurrent 1 Polarizing
7283
Neutral Directional Overcurrent 1 Forward ECA
7284
Neutral Directional Overcurrent 1 Forward Limit Angle
7285
Neutral Directional Overcurrent 1 Forward Pickup
7286
Neutral Directional Overcurrent 1 Reverse Limit Angle
7287
Neutral Directional Overcurrent 1 Reverse Pickup
7288
Neutral Directional Overcurrent 1 Target
7289
Neutral Directional Overcurrent 1 Block
728A
Neutral Directional Overcurrent 1 Events
728B
Neutral Directional Overcurrent 1 Polarizing Voltage
728C
Neutral Directional Overcurrent 1 Op Current
728D
Neutral Directional Overcurrent 1 Offset
728E
Neutral Directional Overcurrent 1 Pos Seq Restraint
728F
Reserved
Breaker Arcing Current Settings (Read/Write Setting) (4 modules)
72C0
Breaker 1 Arcing Current Function
72C1
Breaker 1 Arcing Current Source
72C2
Breaker 1 Arcing Current Initiate A
72C3
Breaker 1 Arcing Current Initiate B
72C4
Breaker 1 Arcing Current Initiate C
72C5
Breaker 1 Arcing Current Delay
72C6
Breaker 1 Arcing Current Limit
72C7
Breaker 1 Arcing Current Block
72C8
Breaker 1 Arcing Current Target
72C9
Breaker 1 Arcing Current Events
72CA
...Repeated for Breaker 2 Arcing Current
72D4
...Repeated for Breaker 3 Arcing Current
72DE
...Repeated for Breaker 4 Arcing Current
DCmA Inputs (Read/Write Setting) (24 modules)
7300
DCmA Inputs 1 Function
7301
DCmA Inputs 1 ID
7307
Reserved 1 (4 items)
B-40
RANGE
-90 to 90
0 to 5
-40 to 40
0 to 1
0.02 to 500
30 to 90
0 to 65535
0 to 1
0 to 5
0 to 65535
0 to 359
0 to 3
0 to 1
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 2
-90 to 90
40 to 90
0.006 to 30
40 to 90
0.006 to 30
0 to 2
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 250
0 to 0.5
0 to 1
0 to 1
0 to 5
0 to 65535
0 to 65535
0 to 65535
0 to 65.535
0 to 50000
0 to 65535
0 to 2
0 to 1
0 to 1
---
0 to 65535
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
degrees
1
F002
pu
0.001
F001
degrees
0.1
F002
---
1
F521
ohms
0.01
F001
degrees
1
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
degrees
1
F001
pu
0.001
F001
---
1
F126
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F230
° Lag
1
F002
degrees
1
F001
pu
0.001
F001
degrees
1
F001
pu
0.001
F001
---
1
F109
---
1
F300
---
1
F102
---
1
F231
---
1
F196
ohms
0.01
F001
---
0.001
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
2
kA
-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F205
---
1
F001
DEFAULT
0
0
0
0 (Zero-seq)
200
85
0
0 (Disabled)
0 (SRC 1)
0
30
700
0 (No)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Voltage)
75
90
50
90
50
0 (Self-reset)
0
0 (Disabled)
0 (Calculated V0)
0 (Calculated 3I0)
0
63
0
0 (Disabled)
0 (SRC 1)
0
0
0
0
1000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"DCmA Ip 1"
0
GE Multilin