2 PRODUCT DESCRIPTION
The order codes for the reduced size vertical mount units with the process bus module are shown below.
Table 2–6: T60 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
T60
-
*
**
- *
*
* - F
BASE UNIT
T60
|
|
|
|
|
CPU
E
|
|
|
|
J
|
|
|
|
K
|
|
|
|
N
|
|
|
|
SOFTWARE
00
|
|
|
01
|
|
|
03
|
|
|
04
|
|
|
06
|
|
|
07
|
|
|
10
|
|
|
11
|
|
|
33
|
|
|
34
|
|
|
MOUNT/COATING
V
|
|
B
|
|
FACEPLATE/ DISPLAY
F
|
D
|
R
|
A
|
K
|
M
|
Q
|
U
|
L
|
N
|
T
|
V
|
POWER SUPPLY
H
L
PROCESS BUS MODULE
DIGITAL INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
GE Multilin
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
|
|
|
|
Base Unit
|
|
|
|
RS485 and RS485
|
|
|
|
RS485, multi-mode ST 100Base-FX and 10/100Base-T
|
|
|
|
RS485, multi-mode ST redundant 100Base-FX and 10/100Base-T
|
|
|
|
RS485 and 10/100Base-T
|
|
|
|
No Software Options
|
|
|
|
Ethernet Global Data (EGD); not available for Type E CPUs
|
|
|
|
IEC 61850; not available for Type E CPUs
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850; not available for Type E CPUs
|
|
|
|
Phasor Measurement Unit (PMU)
|
|
|
|
Phasor Measurement Unit (PMU) and IEC61850
|
|
|
|
Synchrocheck
|
|
|
|
Synchrocheck and IEC 61850; not available for Type E CPUs
|
|
|
|
Phasor Measurement Unit (PMU) and synchrocheck
|
|
|
|
Phasor Measurement Unit (PMU), IEC 61850 protocol, and synchrocheck
|
|
|
|
Vertical (3/4 rack)
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
|
|
|
|
English display
|
|
|
|
French display
|
|
|
|
Russian display
|
|
|
|
Chinese display
|
|
|
|
Enhanced front panel with English display
|
|
|
|
Enhanced front panel with French display
|
|
|
|
Enhanced front panel with Russian display
|
|
|
|
Enhanced front panel with Chinese display
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
|
|
|
125 / 250 V AC/DC power supply
|
|
|
|
24 to 48 V (DC only) power supply
|
81
|
|
Eight-port digital process bus module
XX
XX
XX
XX
No Module
4A
|
4 Solid-State (no monitoring) MOSFET outputs
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
4D
|
16 digital inputs with Auto-Burnishing
4L
|
14 Form-A (no monitoring) Latching outputs
67
|
8 Form-A (no monitoring) outputs
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
|
8 Form-C outputs
6D
|
16 digital inputs
6E
|
4 Form-C outputs, 8 digital inputs
6F
|
8 Fast Form-C outputs
6G
|
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
|
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
|
4 Form-C and 4 Fast Form-C outputs
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
|
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
|
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
|
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
|
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
2A
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
72
1550 nm, single-mode, LASER, 1 Channel
73
1550 nm, single-mode, LASER, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
75
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multi-mode, LED, 1 Channel
7B
1300 nm, multi-mode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, LASER, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multi-mode, LED, 2 Channels
7I
1300 nm, multi-mode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, LASER, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
T60 Transformer Protection System
2.1 INTRODUCTION
2
2-7

Advertisement

Table of Contents
loading