GE UR T60 Instruction Manual page 577

Ur series transformer protection system
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 31 of 65)
ADDR
REGISTER NAME
7048
Reserved (8 items)
Distance (Read/Write Grouped Setting)
7060
Distance Signal Source
7061
Memory Duration
7062
Force Self-Polarization
7063
Force Memory Polarization
Phase Distance (Read/Write Grouped Setting (3 modules)
7070
Phase Distance Zone 1 Function
7071
Phase Distance Zone 1 Current Supervision
7072
Phase Distance Zone 1 Reach
7073
Phase Distance Zone 1 Direction
7074
Phase Distance Zone 1 Comparator Limit
7075
Phase Distance Zone 1 Delay
7076
Phase Distance Zone 1 Block
7077
Phase Distance Zone 1 Target
7078
Phase Distance Zone 1 Events
7079
Phase Distance Zone 1 Shape
707A
Phase Distance Zone 1 RCA
707B
Phase Distance Zone 1 DIR RCA
707C
Phase Distance Zone 1 DIR Comp Limit
707D
Phase Distance Zone 1 Quad Right Blinder
707E
Phase Distance Zone 1 Quad Right Blinder RCA
707F
Phase Distance Zone 1 Quad Left Blinder
7080
Phase Distance Zone 1 Quad Left Blinder RCA
7081
Phase Distance Zone 1 Volt Limit
7082
Phase Distance Zone 1 Transformer Voltage Connection
7083
Phase Distance Zone 1 Transformer Current Connection
7084
Phase Distance Zone 1 Rev Reach
7085
Phase Distance Zone 1 Rev Reach RCA
7086
Reserved (10 items)
7090
...Repeated for Phase Distance Zone 2
70B0
...Repeated for Phase Distance Zone 3
Ground Distance (Read/Write Grouped Setting) (3 modules)
7130
Ground Distance Zone 1 Function
7131
Ground Distance Zone 1 Current Supervision
7132
Ground Distance Zone 1 Reach
7133
Ground Distance Zone 1 Direction
7134
Ground Distance Zone 1 Comparator Limit
7135
Ground Distance Zone 1 Delay
7136
Ground Distance Zone 1 Block
7137
Ground Distance Zone 1 Target
7138
Ground Distance Zone 1 Events
7139
Ground Distance Zone 1 Shape
713A
Ground Distance Zone 1 Z0 Z1 Magnitude
713B
Ground Distance Zone 1 Z0 Z1 Angle
713C
Ground Distance Zone 1 RCA
713D
Ground Distance Zone 1 DIR RCA
713E
Ground Distance Zone 1 DIR Comp Limit
713F
Ground Distance Zone 1 Quad Right Blinder
7140
Ground Distance Zone 1 Quad Right Blinder RCA
7141
Ground Distance Zone 1 Quad Left Blinder
7142
Ground Distance Zone 1 Quad Left Blinder RCA
7143
Ground Distance Zone 1 Z0M Z1 Magnitude
GE Multilin
RANGE
0 to 1
0 to 5
5 to 25
0 to 65535
0 to 65535
0 to 1
0.05 to 30
0.02 to 500
0 to 2
30 to 90
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 1
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 5
0 to 12
0 to 12
0.02 to 500
30 to 90
---
0 to 1
0.05 to 30
0.02 to 500
0 to 2
30 to 90
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 10
-90 to 90
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 7
T60 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F167
cycles
1
F001
---
1
F300
---
1
F300
---
1
F102
pu
0.001
F001
ohms
0.01
F001
---
1
F154
degrees
1
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F120
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
pu
0.001
F001
---
1
F153
---
1
F153
ohms
0.01
F001
degrees
1
F001
---
---
F001
---
1
F102
pu
0.001
F001
ohms
0.01
F001
---
1
F154
degrees
1
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F120
---
0.01
F001
degrees
1
F002
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
---
0.01
F001
DEFAULT
0
0 (SRC 1)
10
0
B
0
0 (Disabled)
200
200
0 (Forward)
90
0
0
0 (Self-reset)
0 (Disabled)
0 (Mho)
Fixed in G60
85
85
90
1000
85
1000
85
0
0 (None)
0 (None)
200
85
0
0 (Disabled)
200
200
0 (Forward)
90
0
0
0 (Self-reset)
0 (Disabled)
0 (Mho)
270
0
85
85
90
1000
85
1000
85
0
B-39

Advertisement

Table of Contents
loading

Table of Contents