Power Ratings - Omron 3G3RX Quick Start Manual

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

SPECIFICATIONS

1.3 Power ratings

Item
3G3RX inverters, 200 V models
A2004
at CT
Max. applicable
kW
motor 4P
at VT
at CT
200 V
at VT
Rated output
capacity (kVA)
at CT
240 V
at VT
Rated input voltage
Rated output voltage
at CT
Rated output current (A)
at VT
Radio noise filter
Weight (kg)
Regenerative
braking
Braking
Minimum
connection
resistance ()
Item
3G3RX inverters, 400 V models
A4004
at CT
Max. applicable
kW
motor 4P
at VT
at CT
400 V
at VT
Rated output
capacity (kVA)
at CT
480 V
at VT
Rated input voltage
Rated output voltage
at CT
Rated output current (A)
at VT
Radio noise filter
Weight (kg)
Regenerative
braking
Braking
Minimum
connection
resistance ()
Item
Three-phase 400 V class specifications
3G3RX inverters, 400 V models
B4750
at CT
Max. applicable
kW
motor 4P
at VT
at CT
400 V
at VT
Rated output
capacity (kVA)
at CT
480 V
at VT
Rated input voltage
Rated output voltage
at CT
Rated output current (A)
at VT
Radio noise filter
Weight (kg)
Regenerative
braking
Braking
Minimum
connection
resistance ()
RX Quick Start Guide
A2007
A2015
A2022
A2037
0.4
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
5.5
1.0
1.7
2.5
3.6
5.7
1.3
2.1
3.2
4.1
6.7
1.2
2.0
3.1
4.3
6.8
1.5
2.6
3.9
5.0
8.1
3-phase: 200 to 240 V (Cannot exceed that of incoming voltage.)
3.0
5.0
7.5
10.5
16.5
3.7
6.3
9.4
12
19.6
3.5
3.5
3.5
3.5
3.5
Built-in braking resistor circuit (discharge resistor separately mounted)
50
50
35
35
35
A4007
A4015
A4022
A4040
0.4
0.75
1.5
2.2
4.0
0.75
1.5
2.2
4.0
5.5
1.0
1.7
2.5
3.6
6.2
1.3
2.1
3.3
4.6
7.7
1.2
2.0
3.1
4.3
7.4
1.5
2.5
4.0
5.5
9.2
3-phase: 380 to 480 V (Cannot exceed that of incoming voltage.)
1.5
2.5
3.8
5.3
9.0
1.9
3.1
4.8
6.7
11.1
3.5
3.5
3.5
3.5
3.5
Built-in braking resistor circuit (discharge resistor)
100
100
100
100
70
B4900
B411K
B413K
75
90
110
132
90
110
132
160
103.2
121.9
150.3
180.1
110.8
135
159.3
200.9
128.3
146.3
180.4
216.1
133
162.1
191.2
241.1
3-phase (3-wire) 380 V -15% to 480V
+10%, 50/60 Hz ±5%
3-phase: 380 to 480 V (Cannot exceed
that of incoming voltage.)
149
176
217
260
160
195
230
290
Built-in
60
60
80
80
Regenerative braking unit separately
mounted
-
-
-
-
Three-phase 200 V class specifications
A2055
A2075
A2110
A2150
5.5
7.5
11
15
7.5
11
15
18.5
8.3
11.0
15.9
22.1
10.4
15.2
20.0
26.3
9.9
13.3
19.1
26.6
12.4
18.2
24.1
31.5
3-phase (3-wire) 200 V -15% to 240 V +10%, 50/60 Hz ±5%
24
32
46
64
30
44
58
73
Built-in
6
6
6
14
16
10
10
7.5
Three-phase 400 V class specifications
A4055
A4075
A4110
A4150
5.5
7.5
11
15
7.5
11
15
18.5
9.7
13.1
17.3
22.1
11.0
15.2
20.9
25.6
11.6
15.8
20.7
26.6
13.3
18.2
24.1
30.7
3-phase (3-wire) 380 V -15% to 480V +10%, 50/60 Hz ±5%
14
19
25
32
16
22
29
37
Built-in
6
6
6
14
70
35
35
24
A2185
A2220
A2300
A2370
A2450
18.5
22
30
37
22
30
37
45
26.3
32.9
41.9
50.2
63.0
29.4
39.1
49.5
59.2
72.7
31.5
39.4
50.2
60.2
75.6
35.3
46.9
59.4
71.0
87.2
76
95
121
145
85
113
140
169
14
14
22
30
Regenerative braking unit separately
mounted
7.5
5
-
-
A4185
A4220
A4300
A4370
A4450
18.5
22
30
37
22
30
37
45
26.3
33.2
40.1
51.9
63.0
30.4
39.4
48.4
58.8
72.7
31.5
39.9
48.2
62.3
75.6
36.5
47.3
58.1
70.6
87.2
38
48
58
75
43
57
70
85
14
14
22
30
Regenerative braking unit separately
mounted
24
20
-
-
A2550
45
55
55
75
76.2
93.5
91.4
112.2
182
220
210
270
30
43
-
-
A4550
45
55
55
75
77.6
93.5
93.1
112.2
91
112
105
135
30
30
-
-
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents