Omron 3G3RX Quick Start Manual page 40

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

RX Quick Start Guide
Function code
Function name
A032
Multi-step speed reference 12
A033
Multi-step speed reference 13
A034
Multi-step speed reference 14
A035
Multi-step speed reference 15
A038
Jogging frequency
A039
Jogging stop selection
A041
Torque boost selection
A241
2nd torque boost selection
A042
Manual torque boost voltage
A242
2nd manual torque boost voltage
A342
3rd manual torque boost voltage
A043
Manual torque boost frequency
A243
2nd manual torque boost frequency
A343
3rd manual torque boost frequency
A044
V/F characteristics selection
A244
2nd V/F characteristics selection
A344
3rd V/F characteristics selection
A045
Output voltage gain
A046
Automatic torque boost voltage compensation gain
A246
2nd automatic torque boost voltage compensation
gain
A047
Automatic torque boost slip compensation gain
A247
2nd automatic torque boost slip compensation gain
A051
DC injection braking selection
A052
DC injection braking frequency
A053
DC injection braking delay time
A054
DC injection braking power
A055
DC injection braking time
A056
DC injection braking method selection
A057
Startup DC injection braking power
A058
Startup DC injection braking time
A059
DC injection braking carrier frequency
A061
Frequency upper limit
A261
2nd frequency upper limit
A062
Frequency lower limit
A262
2nd frequency lower limit
A063
Jump frequency 1
A064
Jump frequency width 1
A065
Jump frequency 2
A066
Jump frequency width 2
38
Monitoring and setting items
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to 9.99
00: FRS (Free running on jogging stop/disabled in opera-
tion)
01: DEC (Deceleration stop on jogging stop/disabled in
operation)
02: DB (DC injection braking on jogging stop/disabled in
operation)
03: FRS (RUN) (Free running on jogging stop/enabled in
operation)
04: DEC (RUN) (Deceleration stop on jogging stop/
enabled in operation)
05: DB (RUN) (DC injection braking on jogging stop/
enabled in operation)
00: Manual torque boost
01: Automatic torque boost
00: Manual torque boost
01: Automatic torque boost
0.0 to 20.0
0.0 to 20.0
0.0 to 20.0
0.0 to 50.0
0.0 to 50.0
0.0 to 50.0
00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
02: Free V/F (characteristics)
03: SLV (Sensorless vector control)
04: 0SLV (0-Hz sensorless vector control)
05: V2 (Sensor vector control)
00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
02: Free V/F (characteristics)
03: SLV (Sensorless vector control)
04: 0SLV (0-Hz sensorless vector control)
05: V2 (Sensor vector control)
00: VC (Constant torque characteristics)
01: VP (Special reduced torque characteristics)
20 to 100
0 to 255
0 to 255
0 to 255
0 to 255
00: OFF (Disabled)
01: ON (Enabled)
02: ON (FQ) (Frequency control [A052 set value])
0.00 to 400.00
0.0 to 5.0
0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
0.0 to 60.0
00: Edge operation
01: Level operation
0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
0.0 to 60.0
0.5 to 15.0 (0.4 to 55 kW)
0.5 to 10.0 (75 to 132 kW)
0.00/frequency lower limit to max frequency
0.00/2nd frequency lower limit to 2nd max frequency
0.00/starting frequency to frequency upper limit
0.00/starting frequency to 2nd frequency upper limit
0.0 to 400.0
0.0 to 10.00
0.0 to 400.00
0.0 to 10.00
Units
Run
Modbus
Default
mode
Register
edit
Hz
122Eh
0.00
122Fh
Hz
1230h
0.00
1231h
Hz
1232h
0.00
1233h
Hz
1234h
0.00
1235h
Hz
1238h
6.00
-
1239h
04
123Bh
00
223Bh
00
%
123Ch
1.0
%
223Ch
1.0
%
323Ch
1.0
%
123Dh
5.0
%
223Dh
5.0
%
323Dh
5.0
123Eh
00
223Eh
00
323Eh
00
%
123Fh
100
1240h
100
2240h
100
1241h
100
2241h
100
1245h
01
Hz
1246h
0.50
s
1247h
0.0
%
1248h
50
40
s
1249h
0.5
124Ah
01
%
124Bh
s
124Ch
0.0
kHz
124Dh
5.0
3.0
Hz
124Fh
0.00
1250h
Hz
224Fh
0.00
2250h
Hz
1251h
0.00
1252h
Hz
2251h
0.00
2252h
Hz
1253h
0.00
1254h
Hz
1255h
0.50
Hz
1256h
0.00
1257h
Hz
1258h
0.50
RX Quick Start Guide
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents