PARAMETER LIST
Function code
Function name
C103
Reset frequency matching selection
C105
FM gain setting
C106
AM gain setting
C107
AMI gain setting
C109
AM bias setting
C110
AMI bias setting
C111
Overload warning level 2
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
C130
Output 11 ON delay
C131
Output 11 OFF delay
C132
Output 12 ON delay
C133
Output 12 OFF delay
C134
Output 13 ON delay
C135
Output 13 OFF delay
C136
Output 14 ON delay
C137
Output 14 OFF delay
C138
Output 15 ON delay
C139
Output 15 OFF delay
C140
Relay output ON delay
C141
Relay output OFF delay
C142
Logic output signal 1 selection 1
C143
Logic output signal 1 selection 2
C144
Logic output signal 1 operator selection
C145
Logic output signal 2 selection 1
C146
Logic output signal 2 selection 2
C147
Logical output signal 2 operator selection
C148
Logic output signal 3 selection 1
C149
Logic output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logic output signal 4 selection 1
C152
Logic output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logic output signal 5 selection 1
C155
Logic output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logic output signal 6 selection 1
C158
Logic output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time 1
C161
Input terminal response time 2
C162
Input terminal response time 3
C163
Input terminal response time 4
RX Quick Start Guide
Monitoring and setting items
00: 0 Hz start
01: f-match (Frequency matching start)
02: Actv. f-match (Active frequency matching restart)
50 to 200
50 to 200
50 to 200
0 to 100
0 to 100
0.0 to 2.00 x Rated current (0.4 to 55 kW)
0.0 to 1.80 x Rated current (75 to 132 kW)
0 to 65535
0 to 65535
0 to 65535
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
Units
Run
Modbus
Default
mode
Register
edit
No.
–
146Bh
00
%
146Dh
100
%
146Eh
100
%
146Fh
100
%
1471h
0
%
1472h
20
A
1473h
-
–
147Dh
Factory
default
–
147Eh
Factory
default
–
147Fh
Factory
default
s
1486h
0.0
s
1487h
0.0
s
1488h
0.0
s
1489h
0.0
s
148Ah
0.0
s
148Bh
0.0
s
148Ch
0.0
s
148Dh
0.0
s
148Eh
0.0
s
148Fh
0.0
s
1490h
0.0
s
1491h
0.0
–
1492h
00
–
1493h
00
–
1494h
00
–
1495h
00
–
1496h
00
–
1497h
00
–
1498h
00
–
1499h
00
–
149Ah
00
–
149Bh
00
–
149Ch
00
–
149Dh
00
–
149Eh
00
–
149Fh
00
–
14A0h
00
–
14A1h
00
–
14A2h
00
–
14A3h
00
ms
14A4h
1
ms
14A5h
1
ms
14A6h
1
ms
14A7h
1
45