Omron 3G3RX Quick Start Manual page 47

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

PARAMETER LIST
Function code
Function name
C103
Reset frequency matching selection
C105
FM gain setting
C106
AM gain setting
C107
AMI gain setting
C109
AM bias setting
C110
AMI bias setting
C111
Overload warning level 2
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
C130
Output 11 ON delay
C131
Output 11 OFF delay
C132
Output 12 ON delay
C133
Output 12 OFF delay
C134
Output 13 ON delay
C135
Output 13 OFF delay
C136
Output 14 ON delay
C137
Output 14 OFF delay
C138
Output 15 ON delay
C139
Output 15 OFF delay
C140
Relay output ON delay
C141
Relay output OFF delay
C142
Logic output signal 1 selection 1
C143
Logic output signal 1 selection 2
C144
Logic output signal 1 operator selection
C145
Logic output signal 2 selection 1
C146
Logic output signal 2 selection 2
C147
Logical output signal 2 operator selection
C148
Logic output signal 3 selection 1
C149
Logic output signal 3 selection 2
C150
Logical output signal 3 operator selection
C151
Logic output signal 4 selection 1
C152
Logic output signal 4 selection 2
C153
Logical output signal 4 operator selection
C154
Logic output signal 5 selection 1
C155
Logic output signal 5 selection 2
C156
Logical output signal 5 operator selection
C157
Logic output signal 6 selection 1
C158
Logic output signal 6 selection 2
C159
Logical output signal 6 operator selection
C160
Input terminal response time 1
C161
Input terminal response time 2
C162
Input terminal response time 3
C163
Input terminal response time 4
RX Quick Start Guide
Monitoring and setting items
00: 0 Hz start
01: f-match (Frequency matching start)
02: Actv. f-match (Active frequency matching restart)
50 to 200
50 to 200
50 to 200
0 to 100
0 to 100
0.0 to 2.00 x Rated current (0.4 to 55 kW)
0.0 to 1.80 x Rated current (75 to 132 kW)
0 to 65535
0 to 65535
0 to 65535
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
0.0 to 100.0
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
Same as options for C021 to C026
(excluding LOG1 to LOG6)
Same as options for C021 to C026
(excluding LOG1 to LOG6)
00: AND
01: OR
02: XOR
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
Units
Run
Modbus
Default
mode
Register
edit
No.
146Bh
00
%
146Dh
100
%
146Eh
100
%
146Fh
100
%
1471h
0
%
1472h
20
A
1473h
-
147Dh
Factory
default
147Eh
Factory
default
147Fh
Factory
default
s
1486h
0.0
s
1487h
0.0
s
1488h
0.0
s
1489h
0.0
s
148Ah
0.0
s
148Bh
0.0
s
148Ch
0.0
s
148Dh
0.0
s
148Eh
0.0
s
148Fh
0.0
s
1490h
0.0
s
1491h
0.0
1492h
00
1493h
00
1494h
00
1495h
00
1496h
00
1497h
00
1498h
00
1499h
00
149Ah
00
149Bh
00
149Ch
00
149Dh
00
149Eh
00
149Fh
00
14A0h
00
14A1h
00
14A2h
00
14A3h
00
ms
14A4h
1
ms
14A5h
1
ms
14A6h
1
ms
14A7h
1
45