PARAMETER LIST

4.2 Parameter group A

Function code
Function name
A001
Frequency reference selection
A002
Run command selection
A003
Base frequency
A203
2nd set base frequency
A303
3rd set base frequency
A004
Maximum frequency
A204
2nd maximum frequency
A304
3rd maximum frequency
A005
O/OI selection
A006
O2 selection
A011
O start frequency
A012
O end frequency
A013
O start ratio
A014
O end ratio
A015
O start selection
A016
O, O2, OI sampling
A017
Drive programming (EzSQ) selection
A019
Multi-step speed selection
A020
Multi-step speed reference 0
A220
2nd multi-step speed reference 0
A320
3rd multi-step speed reference 0
A021
Multi-step speed reference 1
A022
Multi-step speed reference 2
A023
Multi-step speed reference 3
A024
Multi-step speed reference 4
A025
Multi-step speed reference 5
A026
Multi-step speed reference 6
A027
Multi-step speed reference 7
A028
Multi-step speed reference 8
A029
Multi-step speed reference 9
A030
Multi-step speed reference 10
A031
Multi-step speed reference 11
RX Quick Start Guide
Monitoring and setting items
00: VR (Digital operator (FREQ adjuster))
01: Terminal
02: Digital operator (F001)
03: RS485 (Modbus communication)
04: Option 1
05: Option 2
06: Pulse train frequency
07: EzSQ (Drive programming)
10: (Math) Operation function result
01: Terminal
02: Digital operator (F001)
03: RS485 (Modbus communication)
04: Option 1
05: Option2
30 to maximum frequency [A004]
30 to 2nd maximum frequency [A204]
30 to 3rd maximum frequency [A304]
A003 to 400
A203 to 400
A303 to 400
00: [O]/[OI] switches between O/OI terminal AT
01: [O]/[O2] switches between O/O2 terminal AT
02: [O]/VR switches between O/FREQ adjuster via ter-
minal AT (enabled only when 3G3AX-OP01 is used)
03: [OI]/VR switches between OI/FREQ adjuster via ter-
minal AT (enabled only when 3G3AX-OP01 is used)
04: [O2]/VR switches between O2/FREQ adjuster via ter-
minal AT (enabled only when 3G3AX-OP01 is used)
00: [O2] only
01: [O/OI-P] auxiliary frequency reference (not revers-
ible)
02: [O/OI-PM] auxiliary frequency reference (reversible)
03: [OFF] O2 disabled
0.00 to 400.00
0.00 to 400.00
0 to 100
0 to 100
00: External start frequency (A011 set value)
01: 0 Hz
1 to 30
31 (with 500 ms filter ±0.1 Hz hysteresis)
00: Disable
01: [PRG] start
02: Always ON
00: Binary: 16-step selection with 4 terminals
01: Bit: 8-step selection with 7 terminals
0.00 to max frequency [A004]
0.00 to max frequency [A204]
0.00 to max frequency [A304]
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
0.00/starting frequency to max frequency
Units
Run
Modbus
Default
mode
Register
edit
1201h
01
1202h
01
Hz
1203h
50
Hz
2203h
50
Hz
3203h
50
Hz
1204h
50
Hz
2204h
50
Hz
3204h
50
1205h
00
1206h
03
Hz
120Bh
0.00
120Ch
Hz
120Dh
0.00
120Eh
%
120Fh
0
%
1210h
100
1211h
01
1212h
31
1213h
00
1215h
00
Hz
1216h
6.00
1217h
Hz
2216h
6.00
2217h
Hz
3216h
6.00
3217h
Hz
1218h
0.00
1219h
Hz
121Ah
0.00
121Bh
Hz
121Ch
0.00
121Dh
Hz
121Eh
0.00
121Fh
Hz
1220h
0.00
1221h
Hz
1222h
0.00
1223h
Hz
1224h
0.00
1225h
Hz
1226h
0.00
1227h
Hz
1228h
0.00
1229h
Hz
122Ah
0.00
122Bh
Hz
122Ch
0.00
122Dh
37