Parameter Group B - Omron 3G3RX Quick Start Manual

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

RX Quick Start Guide
Function code
Function name
A105
OI start selection
A111
O2 start frequency
A112
O2 end frequency
A113
O2 start ratio
A114
O2 end ratio
A131
Acceleration curve parameter
A132
Deceleration curve parameter
A141
Operation frequency input A setting
A142
Operation frequency input B setting
A143
Operator selection
A145
Frequency addition amount
A146
Frequency addition direction
A150
EL-S-curve ratio 1 during acceleration
A151
EL-S-curve ratio 2 during acceleration
A152
EL-S-curve ratio 1 during deceleration
A153
EL-S-curve ratio 2 during deceleration

4.3 Parameter group B

Function code
Function name
b001
Retry selection
b002
Allowable momentary power interruption time
b003
Retry wait time
b004
Momentary power interruption/undervoltage trip
during stop selection
b005
Momentary power interruption retry time selection
b006
Input phase loss protection selection
b007
Frequency matching lower limit frequency setting
b008
Trip retry selection
b009
Undervoltage retry time selection
b010
Overvoltage/overcurrent retry time selection
b011
Trip retry wait time
b012
Electronic thermal level
b212
2nd electronic thermal level
b312
3rd electronic thermal level
b013
Electronic thermal characteristics selection
40
Monitoring and setting items
00: Start FQ (Use OI start frequency [A101])
01: 0 Hz
-400.00 to 400.00
-400.00 to 400.00
-100 to O2 end ratio
O2 start ratio to 100
01 (small curve) to 10 (large curve)
01 (small curve) to 10 (large curve)
00: Operator (Digital operator (F001))
01: VR (Digital operator (FREQ adjuster)) (Enabled
when 3G3AX-OP01 is used)
02: O (Input O)
03: OI (Input OI)
04: Modbus (RS485 communication)
05: Option 1
06: Option 2
07: Pulse (Pulse train frequency)
00: Operator (Digital operator (F001))
01: VR (Digital operator (FREQ adjuster)) (Enabled
when 3G3AX-OP01 is used)
02: O (Input O)
03: OI (Input OI)
04: Modbus (RS485 communication)
05: Option 1
06: Option 2
07: Pulse (Pulse train frequency)
00: ADD (Addition (A + B))
01: SUB (Substraction (A - B))
03: MUL (Multiplication (A x B))
0.00 to 400.00
00: ADD (Add A145 value to output frequency)
01: SUB (Subtract A145 value from output frequency)
0 to 50
0 to 50
0 to 50
0 to 50
Monitoring and setting items
00: TRIP (Alarm)
01: 0 Hz start
02: f-match (Frequency matching start)
03: f-match trip (Trip after frequency matching decelera-
tion stop)
04: Actv. f-match (Active frequency matching restart)
0.3 to 25.0
0.3 to 100.0
00: OFF (Disabled)
01: ON (Enabled)
02: Decel-OFF (Disabled during stop and deceleration
stop)
00: 16 times
01: No limit
00: OFF (Disabled)
01: ON (Enabled)
0.00 to 400.00
00: TRIP (Alarm)
01: 0 Hz start
02: f-match (Frequency matching start)
03: f-match trip (Trip after frequency matching decelera-
tion stop)
04: Actv. f-match (Active frequency matching restart)
00: 16 times
01: No limit
1 to 3
0.3 to 100.0
0.20 x Rated current to 1.00 x Rated current
0.20 x Rated current to 1.00 x Rated current
0.20 x Rated current to 1.00 x Rated current
00: Reduced TRQ (Reduced torque characteristics)
01: Const TRQ (Constant torque characteristics)
02: Free set (Free setting)
Units
Run
Modbus
Default
mode
Register
edit
1287h
00
Hz
128Dh
0.00
128Eh
Hz
128Fh
0.00
1290h
%
1291h
-100
%
1292h
100
12A5h
02
-
12A6h
02
-
12AFh
02
12B0h
03
12B1h
00
Hz
12B3h
0.00
12B4h
12B5h
00
%
12B9h
10
%
12BAh
10
%
12BBh
10
%
12BCh
10
Units
Run
Modbus
Default
mode
Register
edit
No.
1301h
s
1302h
1.0
s
1303h
1.0
1304h
1305h
1306h
Hz
1307h
0.00
1308h
1309h
130Ah
Time
130Bh
s
130Ch
1.0
A
130Dh
A
230Ch
A
330Ch
130Eh
RX Quick Start Guide
00
00
00
00
00
00
3
-
-
-
00