PARAMETER LIST
Function code
Function name
b213
2nd electronic thermal characteristics selection
b313
3rd electronic thermal characteristics selection
b015
Free setting, electronic thermal frequency 1
b016
Free setting, electronic thermal current 1
b017
Free setting, electronic thermal frequency 2
b018
Free setting, electronic thermal current 2
b019
Free setting, electronic thermal frequency 3
b020
Free setting, electronic thermal current 3
b021
Overload limit selection
b022
Overload limit level
b023
Overload limit parameter
b024
Overload limit selection 2
b025
Overload limit level 2
b026
Overload limit parameter 2
b027
Overcurrent suppression function
b028
Active frequency matching restart level
b029
Active frequency matching restart parameter
b030
Starting frequency at active frequency matching
restart
b031
Soft lock selection
b034
RUN time/Power ON time setting
b035
Rotation direction limit selection
b036
Reduced voltage startup selection
b037
Display selection
b038
Initial screen selection
b039
User parameter automatic setting function selection
b040
Torque limit selection
b041
Torque limit 1
(fwd-power in 4-quadrant mode)
b042
Torque limit 2
(rev/regen. in 4-quadrant mode)
b043
Torque limit 3
(rev/power in 4-quadrant mode)
b044
Torque limit 4
(fwd/regen. in 4-quadrant mode)
b045
Torque LADSTOP selection
RX Quick Start Guide
Monitoring and setting items
00: Reduced TRQ (Reduced torque characteristics)
01: Const TRQ (Constant torque characteristics)
02: Free set (Free setting)
00: Reduced TRQ (Reduced torque characteristics)
01: Const TRQ (Constant torque characteristics)
02: Free set (Free setting)
0.00 to 400.00
0.0 to Rated current
0.00 to 400.00
0.0 to Rated current
0.00 to 400.00
0.0 to Rated current
00: OFF (Disabled)
01: ON-Acc/Cnst (Enabled in acceleration/constant
speed operation)
02: ON-Cnst (Enabled in constant speed operation)
03: ON-A/C(R) (Enabled in acceleration/constant speed
operation (Accelerates during regeneration))
0.20 x Rat current to 2.00 x Rat current (0.4 to 55 kW)
0.20 x Rat current to 1.80 x Rat current (75 to 132 kW)
0.10 to 30.00
00: OFF (Disabled)
01: ON-Acc/Cnst (Enabled in acceleration/constant
speed operation)
02: ON-Cnst (Enabled in constant speed operation)
03: ON-A/C(R) (Enabled in acceleration/constant speed
operation (Accelerates during regeneration))
0.20 x Rat current to 2.00 x Rat current (0.4 to 55 kW)
0.20 x Rat current to 1.80 x Rat current (75 to 132 kW)
0.10 to 30.00
00: OFF (Disabled)
01: ON (Enabled)
0.20 x Rat current to 2.00 x Rat current (0.4 to 55 kW)
0.20 x Rat current to 1.80 x Rat current (75 to 132 kW)
0.10 to 30.00
00: Off FQ (Frequency at interruption)
01: Max.FQ (Max. frequency)
02: Set FQ (Set frequency)
00: Lock (SFT) (Data other than b031 cannot be changed
when terminal SFT is ON)
01: Only FQ (SFT) (Data other than b031 and the speci-
fied frequency parameter cannot be changed when ter-
minal SFT is ON)
02: Lock (Data other than b031 cannot be changed)
03: Only FQ (Data other than b031 and the specified fre-
quency parameter cannot be changed)
10: RUN chg mode (Data other than parameters change-
able during operation cannot be changed)
0 to 65535
00: FREE (Forward and reverse are enabled)
01: FWD (Only forward is enabled)
02: REV (Only reverse is enabled)
0 (reduced voltage startup time: small) to 255 (reduced
voltage startup time: large)
00: All (Complete display)
01: Utilized (Individual display of functions)
02: User (User setting)
03: Compare (Data comparison display)
04: Basic (Basic display)
000 to 202
00: OFF (Disabled)
01: ON (Enabled)
00: 4-quadrant (Four-quadrant separate setting)
01: TRQ input (Terminal switch)
02: [O] input (Analogue input)
03: Option 1
04: Option 2
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
no (Torque limit disabled)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
no (Torque limit disabled)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
no (Torque limit disabled)
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
no (Torque limit disabled)
00: OFF (Disabled)
01: ON (Enabled)
Units
Run
Modbus
Default
mode
Register
edit
No.
230Dh
00
330Dh
00
Hz
1310h
0.00
A
1311h
0.00
Hz
1312h
0.00
A
1313h
0.00
Hz
1314h
0.00
A
1315h
0.00
1316h
01
A
1317h
-
s
1318h
1.00
1319h
01
A
131Ah
-
s
131Bh
1.00
131Ch
00
A
131Dh
-
s
131Eh
0.50
131Fh
00
1320h
01
h
1323h
0
1324h
1325h
00
1326h
6
1327h
00
1328h
001
1329h
00
132Ah
00
%
132Bh
150
%
132Ch
150
%
132Dh
150
%
132Eh
150
132Fh
00
41