Omron 3G3RX Quick Start Manual page 50

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

RX Quick Start Guide
Function code
Function name
P034
Torque reference setting
P035
Polarity selection at torque reference via O2
P036
Torque bias mode
P037
Torque bias value
P038
Torque bias polarity selection
P039
Speed limit value in torque control (forward)
P040
Speed limit value in torque control (reverse)
P044
DeviceNet comm watch dog timer
P045
Operation setting at communications error
P046
Instance number
P048
Operation setting at idle mode detection
P049
Polarity setting for rotation speed
P055
Pulse train frequency scale
P056
Pulse train frequency filter time constant
P057
Pulse train frequency bias amount
P058
Pulse train frequency limit
P060
Multi-step position command 0
P061
Multi-step position command 1
P062
Multi-step position command 2
P063
Multi-step position command 3
P064
Multi-step position command 4
P065
Multi-step position command 5
P066
Multi-step position command 6
P067
Multi-step position command 7
P068
Zero return mode
P069
Zero return direction selection
P070
Low-speed zero return frequency
P071
High-speed zero return frequency
P072
Position range specification (forward)
P073
Position range specification (reverse)
P074
Teaching selection
P100
Drive program parameter U(00)
P101
Drive program parameter U(01)
48
Monitoring and setting items
0 to 200 (0.4 to 55 kW)
0 to 180 (75 to 132 kW)
00: Sign (Signed)
01: Direction (Depends on the RUN direction)
00: OFF (None)
01: OPE (Digital operator)
02: O2 (Terminal O2)
05: Option 1
06: Option 2
-200 to 200 (0.4 to 55 kW)
-180 to 180 (75 to 132 kW)
00: Sign (Signed)
01: Direction (Depends on the RUN direction)
0.00 to maximum frequency
0.00 to maximum frequency
0.00 to 99.99
00: Trip
01: Decel-Trip (Trip after deceleration stop)
02: Ignore
03: Free RUN
04: Decel-Stop (Deceleration stop)
0: Basic speed I/O
1: Extended speed I/O
2: Extended speed and torque control
3: Special I/O
4: Extended control I/O
5: Extended control I/O and multifunction I/O monitor
6: Flexible format
7: Extended speed and acceleration control
8-20: Not used
00: Trip
01: Decel-Trip (Trip after deceleration stop)
02: Ignore
03: Free RUN
04: Decel-Stop (Deceleration stop)
0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/32/34/36/
38
1.0 to 50.0
0.01 to 2.00
-100 to 100
0 to 100
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
-268435455 to 268435455
00: Low speed
01: High speed 1
02: High speed 2
00: FWD (Forward side)
01: REV (Reverse side)
0.00 to 10.00
0.00 to maximum frequency
0 to 268435455 (at P012: 02)
0 to 1073741823 (at P012: 03)
-268435455 to 0 (at P012: 02)
-1073741823 to 0 (at P012: 03)
00: X00 (Multi-step position command 0 (P060))
01: X01 (Multi-step position command 1 (P061))
02: X02 (Multi-step position command 2 (P062))
03: X03 (Multi-step position command 3 (P063))
04: X04 (Multi-step position command 4 (P064))
05: X05 (Multi-step position command 5 (P065))
06: X06 (Multi-step position command 6 (P066))
07: X07 (Multi-step position command 7 (P067))
0 to 65535
0 to 65535
Units
Run
Modbus
Default
mode
Register
edit
No
%
1622h
1623h
00
1624h
00
%
1625h
1626h
00
Hz
1627h
0.00
1628h
Hz
1629h
0.00
162Ah
s
162Eh
1.00
162Fh
00
1630h
1632h
00
1633h
kHz
1639h
25.0
s
163Ah
0.10
%
163Bh
%
163Ch
100
-
163Eh
163Fh
1640h
-
1641h
-
1642h
1643h
-
1644h
1645h
-
1646h
1647h
-
1648h
1649h
164Ah
-
164Bh
-
164Ch
164Dh
-
164Eh
00
-
164Fh
00
Hz
1650h
0.00
Hz
1651h
0.00
-
1652h
+26843
1653h
5455
-
1654h
-26843
1655h
5455
1656h
00
-
-
1666h
-
1667h
RX Quick Start Guide
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0