Parameter Group H - Omron 3G3RX Quick Start Manual

200 v class three-phase input 0.4 to 55 kw 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for 3G3RX:
Table of Contents

Advertisement

RX Quick Start Guide
Function code
Function name
C164
Input terminal response time 5
C165
Input terminal response time 6
C166
Input terminal response time 7
C167
Input terminal response time 8
C168
FW terminal response time
C169
Multi-step speed/position determination time

4.5 Parameter group H

Function code
Function name
H001
Auto-tuning selection
H002
Motor parameter selection
H202
2nd motor parameter selection
H003
Motor capacity selection
H203
2nd motor capacity selection
H004
Motor pole number selection
H204
2nd motor pole number selection
H005
Speed response
H205
2nd speed response
H006
Stabilization parameter
H206
2nd stabilization parameter
H306
3rd stabilization parameter
H020
Motor parameter R1
H220
2nd motor parameter R1
H021
Motor parameter R2
H221
2nd motor parameter R2
H022
Motor parameter L
H222
2nd motor parameter L
H023
Motor parameter Io
H223
2nd motor parameter Io
H024
Motor parameter J
H224
2nd motor parameter J
H030
Motor parameter R1 (auto-tuning data)
H230
2nd motor parameter R1 (auto-tuning data)
H031
Motor parameter R2 (auto-tuning data)
H231
2nd motor parameter R2 (auto-tuning data)
H032
Motor parameter L (auto-tuning data)
H232
2nd motor parameter L (auto-tuning data)
46
Monitoring and setting items
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
0 to 200 (x 2 ms)
Monitoring and setting items
00: OFF (Disabled)
01: ON (STOP)
02: ON (Rotation)
00: Standard motor parameter
01: Auto-tuning parameter
02: Auto-tuning parameter (online auto-tuning enabled)
00: Standard motor parameter
01: Auto-tuning parameter
02: Auto-tuning parameter (online auto-tuning enabled)
0.20 to 160.0 (kW)
0.20 to 160.0 (kW)
2/4/6/8/10
2/4/6/8/10
0.001 to 80.000
0.001 to 80.000
0 to 255
0 to 255
0 to 255
0.001 to 65.535
0.001 to 65.535
0.001 to 65.535
0.001 to 65.535
0.01 to 655.35
0.01 to 655.35
0.01 to 655.35
0.01 to 655.35
0.001 to 9999.000
0.001 to 9999.000
0.001 to 65.535
0.001 to 65.535
0.001 to 65.535
0.001 to 65.535
0.01 to 655.35
0.01 to 655.35
Units
Run
Modbus
Default
mode
Register
edit
No.
ms
14A8h
ms
14A9h
ms
14AAh
ms
14ABh
ms
14ACh
ms
14ADh
Units
Run
Modbus
Default
mode
Register
edit
No.
1501h
00
1502h
00
2502h
00
kW
1503h
Factory
default
kW
2503h
Factory
default
Pole
1504h
4P
Pole
2504h
4P
1505h
1.590
1506h
2505h
1.590
2506h
1507h
100
2507h
100
3507h
100
1515h
1516h
2515h
2516h
1517h
1518h
2517h
2518h
mH
1519h
151Ah
mH
2519h
251Ah
A
151Bh
151Ch
A
251Bh
251Ch
2
151Dh
kgm
151Eh
2
251Dh
kgm
251Eh
1524h
1525h
2524h
2525h
1526h
1527h
2526h
2527h
mH
1528h
1529h
mH
2528h
2529h
RX Quick Start Guide
1
1
1
1
1
0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents