Technogym Recline 500SP Service Maintenance Manual page 70

Hide thumbs Also See for Recline 500SP:
Table of Contents

Advertisement

Continued on the following page.
Page 6.10
RECLINE EXCITE: Service & Maintenance Manual - rev. 2.4
A
2
Does the mains v oltage
reach the input to the
brake board?
YES
3
Are the DC v oltages at the
output of the brake board
correct?
YES
4
Are the DC v oltages
correct at the input to:
- the connector board?
- the CPU board (UB
models)?
YES
5
Are the DC v oltages at the
output of the CPU board to
the LCD inv erter correct?
YES
6
Are the DC v oltages at the
input to the LCD inv erter
correct?
YES
B
NO
Replace cable CB-0
NO
Replace Brake board
NO
Replace cable CB-3
NO
Replace the CPU
and/or connector
board
NO
Replace cable:
- CV-302 (NCB models)
- CU98 (UB models)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents